Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

ES
MANUAL DE USUARIO E INSTALACIÓN
EN
OWNER'S AND INSTALLATION MANUAL
FR
MANUEL DE L'UTILISATEUR ET D'INSTALLATION
PT
MANUAL DO UTILIZADOR E INSTALAÇÃO
UNIDAD EXTERIOR | OUTDOOR UNIT
UNITÉ DE L'EXTÉRIEURE | UNIDADE EXTERIOR
IX90S-R32C
HTWS026IX90SR32C-O | HTWS035IX90SR32C-O
HTWS052IX90SR32C-O | HTWS071IX90SR32C-O
Por favor lea atentamente este manual antes de usar este producto.
Please, read carefully this manual before using the product.
Avant d'utiliser l'équipement, lisez attentivement les instructions.
Por favor leia atentamente este manual antes de usar o equipamento.
Per favore leggere attentamente questo manuale prima di utilizzare questo prodotto.
G r a c i a s | T h a n k y o u | M e r c i | O b r i g a d o
Tabla de contenido
loading

Resumen de contenidos para HTW IX90S-R32C

  • Página 1 MANUEL DE L’UTILISATEUR ET D’INSTALLATION MANUAL DO UTILIZADOR E INSTALAÇÃO UNIDAD EXTERIOR | OUTDOOR UNIT UNITÉ DE L’EXTÉRIEURE | UNIDADE EXTERIOR IX90S-R32C HTWS026IX90SR32C-O | HTWS035IX90SR32C-O HTWS052IX90SR32C-O | HTWS071IX90SR32C-O Por favor lea atentamente este manual antes de usar este producto. Please, read carefully this manual before using the product.
  • Página 3: Unidad Exterior

    ESPAÑOL MANUAL DE USUARIO E INSTALACIÓN UNIDAD EXTERIOR IX90S-R32C HTWS026IX90SR32C-O | HTWS035IX90SR32C-O HTWS052IX90SR32C-O | HTWS071IX90SR32C-O...
  • Página 4: Tabla De Contenido

    Contenido Avisos de operación Precaución ....................3 Nombre de las piezas ................... 9 Mal funcionamiento Análisis de fallos ..................10 Aviso de instalación Seguridad para el refrigerante inflamable ..........12 Preparación de la instalación ..............14 Instalación La instalación de la unidad exterior ............18 Compruebe después de la instalación ............
  • Página 5: Precaución

    Precaución ADVERTENCIA Por favor, lea este manual de instrucciones cuidadosamente antes de utilizar la unidad. Aparato lleno de R32 gas inflamable. Antes de utilizar el aparato, lea el manual del usuario en primer lugar. Antes de instalar el aparato, lea el manual de instalación en primer lugar. Antes de reparar el aparato, lea el manual de servicio de primera.
  • Página 6: Operación Y Mantenimiento

    Precaución ADVERTENCIA Operación y mantenimiento Este aparato puede ser utilizado por niños mayores de 8 años y personas con discapacidad física, sensorial o men- tal, o falta de experiencia y conocimiento, si se les ha dado la supervisión o instrucciones relativas al uso del aparato de una manera segura y comprendiendo los peligros.
  • Página 7 Precaución ADVERTENCIA No repare el aire acondicionado por sí mismo. Puede causar una descarga eléctrica o daños. Por favor, póngase en contacto con un distribuidor cuando necesite reparación de aire acondicionado. No extienda los dedos u objetos en la entrada o salida de aire.
  • Página 8 Precaución ADVERTENCIA Debe seguir las normas de seguridad eléctrica al instalar la unidad. De acuerdo con las normas de seguridad locales, utilice un circuito de alimentación calificado. Instale la rotura del circuito. Si no, puede causar un mal funcionamiento. Un interruptor de desconexión de todos los polos con una separación de contacto de al menos 3 mm en todos los polos se debe conectar en un cableado fijo.
  • Página 9 Precaución ADVERTENCIA No enchufe el aparato antes de terminar la instalación. Si el cable de alimentación está dañado, debe ser reemplazado por el fabricante, su agente de servicio o por personal cualificado con el fin de evitar un peligro. La temperatura del circuito de refrigerante será alto, por favor mantenga el cable de interconexión lejos del tubo de cobre.
  • Página 10: Temperatura De Funcionamiento

    Precaución ADVERTENCIA Respecto al enchufe del aire acondicionado, éste debe ser accesible después de terminar la instalación. En el caso del aire acondicionado sin enchufe, necesitará un circuito instalado en línea. Si necesita reubicar el aparato de aire acondicionado a otro lugar, sólo la persona calificada puede realizar el trabajo.
  • Página 11: Nombre De Las Piezas

    Nombre de las piezas Entrada Salida NOTA: El producto real puede ser diferente de los gráficos anteriores, por favor refiérase a los productos reales.
  • Página 12: Análisis De Fallos

    Análisis de fallos Análisis general de fallos Por favor, consulte en la tabla de abajo antes de pedir artículos para el mantenimiento. Si persiste el mal funcionamiento y todavía no puede ser eliminado, por favor, póngase en contacto con el distribuidor local o con profesionales cualificados.
  • Página 13 Análisis de fallos ¿Está la temperatura en Ajuste la temperatura al En refrigeración el rango adecuado? rango correcto. (o en calefacción) no hace el efecto ¿Tiene puertas y Cierre las puertas y deseado. ventanas abiertas? ventanas. desconecte la energía, El aire acondicionado no ¿Hay interferencia, tales poner de nuevo el poder, funciona con normalidad...
  • Página 14: Seguridad Para El Refrigerante Inflamable

    Seguridad para el refrigerante inflamable Requisitos de calificación para el instalador y mantenimiento Todos los técnicos que están participando en el sistema de refrigeración deben tener una certificación válida otorgada por la organización autorizada y con la cualificación adecuada para tratar con el sistema de refrigeración reconocido por esta industria. Si se necesita otro técnico para mantener y reparar el aparato, deben ser supervisado por la persona que lleva la calificación para el uso del refrigerante inflamable.
  • Página 15: Llenado Del Refrigerante

    Seguridad para el refrigerante inflamable Soldadura Si usted debe cortar o soldar las tuberías del sistema de refrigerante en el proceso de mantenimiento, por favor siga los pasos a continuación: 1. Apagar la unidad y cortar la fuente de alimentación. 2.
  • Página 16: Preparación De La Instalación

    Preparación de la instalación Dibujo de la instalación Tubería de drenaje Herramientas 2 Destornillador 3 Taladro del impacto 4 Taladro 5 Expansor de tubo 6 Llave de torsión 8 Cortatubos 9 Detector de fugas 11 Medidor de presión 12 Metro universal 13 Llave hexagonal interior 14 Cinta de medición Selección de los lugares...
  • Página 17: Precauciones De Seguridad

    Preparación de la instalación Unidad exterior 1. Seleccione una ubicación donde el ruido y el flujo de salida de aire emitida por la unidad exterior no afecte al entorno del barrio. 2. El lugar debe estar bien ventilado y seco, en la que no esté expuesta la unidad exterior directamente a la luz solar o un fuerte viento.
  • Página 18 Preparación de la instalación Requisito de puesta a tierra 1. El aire acondicionado es un aparato eléctrico de primera clase. Su puesta a tierra debe ser adecuada con el dispositivo de conexión a tierra especializado y realizado por un profesional. Por favor asegúrese de que siempre está conectado a tierra de manera efectiva, de lo contrario puede provocar una descarga eléctrica.
  • Página 19 Preparación de la instalación 3. Cuando el refrigerante necesita ser recuperado durante la reubicación o la reparación de la unidad, asegúrese de que la unidad está funcionando en modo de refrigeración. A continuación, cierre completamente la válvula del lado en alta presión (válvula de líquido).
  • Página 20: La Instalación De La Unidad Exterior

    Instalación de la unidad exterior exterior Paso 1: Fijar el soporte de aire libre Seleccionarlo de acuerdo a la situación real de la instalación. 1. Seleccionar ubicación de la instalación de acuerdo con la estructura de la casa. 2. Fijar el soporte de la unidad exterior en la posición deseada con tornillos de expansión. Nota: ●...
  • Página 21 Instalación de la unidad exterior exterior Paso 3: Fijar unidad exterior 1. Coloque la unidad exterior sobre el soporte. 2. Fijar los agujeros del pie de la unidad exterior con pernos. agujeros del pie Paso 4: Conecte el tubo interior y exterior 1.
  • Página 22 Instalación de la unidad exterior exterior Paso 5: Conecte el tubo interior y exterior 1. Retire el clip de alambre; conecte el cable de control de alambre y la señal de conexión de alimentación (sólo para la refrigeración y la unidad de calentamiento) a la terminal de cableado de acuerdo con el color, fijarlos con tornillos.
  • Página 23 Instalación de la unidad exterior exterior Paso 7: Bombeo de vacío Usar Bomba de vacío válvula de líquido piezómetro 1. Retire las tapas de válvula en la válvula Lo Hi válvula de gas de líquido y la válvula de gas y la tuerca refrigerante de refrigerante de ventilación de carga.
  • Página 24: Compruebe Después De La Instalación

    Compruebe después de la instalación instalación Compruebe los elementos y acciones necesarias para después de la instalación Elementos a comprobar Un posible mal funcionamiento ¿la unidad se ha instalado firmemente? La unidad puede caer, sacudir o emitir ruido. Puede causar una mala refrigeración ¿Ha hecho la prueba de fugas de (calefacción).
  • Página 25: Funcionamiento

    Funcionamiento 1. Preparación de la operación de prueba ● El cliente aprueba el aire acondicionado. ● Especificar al cliente las notas importantes para el uso del aire acondicionado. 2. Método de operación de prueba ● Conecte la fuente, presione el botón "ON / OFF" en el mando a distancia para iniciar la operación.
  • Página 26: Archivo Adjunto La Configuración Del Tubo De Conexión

    La configuración de la conexión de tubo conexión 1. La longitud estándar del tubo de conexión es de: 5 m, 7,5 m, 8 m. 2. La longitud mínima de la tubería de conexión: Para la unidad con el tubo de conexión estándar de 5m, no hay ninguna limitación para la longitud min de tubo de conexión.
  • Página 27: Método De Expansión De La Tubería

    Método de expansión de la tubería tubería Una inadecuada expansión de tubería es la principal causa de fugas de refrigerante. Por favor, amplie la tubería de acuerdo con los siguientes pasos: A: Cortar el tubo E: ampliar el puerto Confirmar la longitud del tubo de acuerdo Ampliar el puerto con el ampliador.
  • Página 29: Outdoor Unit

    ENGLISH OWNER’S AND INSTALLATION MANUAL OUTDOOR UNIT IX90S-R32C HTWS026IX90SR32C-O | HTWS035IX90SR32C-O HTWS052IX90SR32C-O | HTWS071IX90SR32C-O...
  • Página 30 Content Operation Notices Precautions ......................29 Parts name ......................34 Malfunction Malfunction analysis ..................35 Installation Notice Safety operation of flammable refrigerant ............36 Installation prepare .................... 38 Installation Installation of outdoor unit................42 Check after installation ..................43 Test operation ....................45 Attachment Configuration of connection pipe..............
  • Página 31: Precautions

    Precautions Please read this operating manual carefully before operating the unit. Appliance filled with flammable gas R32. Before use the appliance, read the owner's manual first. Befoer install the appliance,read the installation manual first. Befoer repair the appliance ,read the service manual first. The figures in this manual may be different with the material objects, please refer to the material objects for reference.
  • Página 32 Precautions WARNING Operation and Maintenance This appliance can be used by children aged of 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Página 33 Precautions WARNING Do not block air outlet or air inlet. It may cause malfunction. Do not spill water on the remote controller, otherwise the remote controller may be broken. When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
  • Página 34 Precautions WARNING Including an circuit break with suitable capacity, please note the following table.Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. Don't use unqualified power cord. Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction.
  • Página 35: Working Temperature Range

    Precautions WARNING The appliance must be positioned so that the plug is accessible. All wires of indoor unit and outdoor unit should be connected by a professional. If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
  • Página 36: Parts Name

    Parts name Air inlet Handle Air outlet NOTE: Actual product may be different from above graphics,please refer to actual products.
  • Página 37: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can't be eliminated,please contact local dealer or qualified professionals. Phenomenon Check items Solution Power failure? Wait until power recovery. Is plug loose? Reinsert the plug. Circuit break trips off or fuse is Ask professional to replace circuit burnt out?
  • Página 38: Safety Operation Of Flammable Refrigerant

    Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualificationfor dealing with the refrigeration system recognized by this industry.
  • Página 39 Safety operation of flammable refrigerant Welding If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below: 1. Shut down the unit and cut power supply. 2. Eliminate the refrigerant. 3.
  • Página 40: Installation Prepare

    Installation prepare Installation drawing Drainage pipe Tools 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape...
  • Página 41: Safety Precaution

    Installation prepare Outdoor unit 1. Select a location where the noise and out flow air emitted by the outdoor unit will not affect neighborhood. 2. The location should be well ventilated and dry, in which the outdoor unit won't be exposed directly to sunlight or strong wind.
  • Página 42: Safety Precautions For Installing And Relocating The Unit

    Installation prepare Grounding requirement 1. The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. 2.
  • Página 43 Installation prepare pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute. — If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
  • Página 44: Installation Of Outdoor Unit

    Installation of outdoor unit Step 1: Fix the support of outdoor Select it according to the actual installation situation 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: ●...
  • Página 45 Installation of outdoor unit Step 4: Connect indoor and outdoor pipe 1. Remove the screw on the right handle of 2. Remove the screw cap of valve and aim outdoor unit and then remove the handle. the pipe joint at the bellmouth of pipe. liquid valve gas valve handle...
  • Página 46 Installation of outdoor unit Step 6: Neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min.semidiameter of bending the pipe is 10cm. 2. If the outdoor unit is higher than the wall hole, you must set a U-shaped curve in the pipe before pipe wall goes into the room, in order to prevent rain from...
  • Página 47: Check After Installation

    Check after installation Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage It may cause in sufficient cooling (heating) test? capacity.
  • Página 48: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2. Min length of connection pipe For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
  • Página 49: Pipe Expanding Method

    Pipe expanding method Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port Confirm the pipe length according to the Expand the port with expander. distance of indoor unit and outdoor unit.
  • Página 51 FRANÇAIS MANUEL DE L’UTILISATEUR ET D’INSTALLATION UNITÉ DE L’EXTÉRIEURE IX90S-R32C HTWS026IX90SR32C-O | HTWS035IX90SR32C-O HTWS052IX90SR32C-O | HTWS071IX90SR32C-O...
  • Página 52 Contenu Avis d'opération Précautions ......................5 1 Nom des pièces ....................5 7 Mauvais fonctionnement Analyse de dysfonctionnement ................5 8 Avis d'installation Sécurité du fonctionnement des réfrigérants inflammables......59 Installation ......................61 Installation Installation de l'unité..................65 Vérifiez après l'installation ................69 Test de fonctionnement ..................
  • Página 53: Précautions

    Précautions S'il vous plaît lire ce mode d'emploi avant d'utiliser l'appareil. Appareil rempli de R32 de gaz inflammable. Avant d'utiliser l'appareil, lisez d'abord le manuel du propriétaire. Avant d’installer l'appareil, lisez le manuel d'installation Avant de réparer l'appareil, lisez le manuel de service Les chiffres figurant dans ce manuel peuvent être différents des objets matériels, Veuillez vous reporter aux objets matériels pour référence.
  • Página 54 Précautions ATTENTION Opération et maintenance Cet appareil peut être utilisé par des enfants âgés de 8 ans et les personnes dont les capacités physiques, sensorielles ou mentales ou manque d'expérience et de connaissances si elles ont été supervisées ou instructions concernant l'utilisation de l'appareil de manière sûre et comprendre les risques impliquées Les enfants ne doivent pas jouer avec l'appareil.
  • Página 55 Précautions ATTENTION Ne pas étendre les doigts ou des objets dans l'entrée d'air ou de sortie d'air. Il peut causer des blessures ou des dommages. Ne pas bloquer la sortie d'air ou d'entrée d'air. Il peut provoquer des dysfonctionnements. Ne pas renverser d'eau sur la télécommande, sinon la télécommande peut être rompu.
  • Página 56 Précautions ATTENTION Selon les règles de sécurité locales, utiliser le circuit d'alimentation qualifié et coupure de circuit. Installez le rupture du circuit. Sinon, cela peut provoquer un dysfonctionnement. Un interrupteur de déconnexion sur tous les pôles ayant une séparation de contact de au moins 3 mm sur tous les pôles doit être branché...
  • Página 57 Précautions ATTENTION L'installation doit être effectuée conformément à l'exigence de NEC et CEC par personnel autorisé. La climatisation est un appareil électrique de première classe. Il doit être mise à la terre correctement avec un appareil de mise à la terre spécialisée par un professionnel. S'il vous plaît assurez-vous qu'il est toujours mis à...
  • Página 58: Température De Fonctionnement

    Précautions ATTENTION Température de fonctionnement Côté intérieur DB / WB (° Côté extérieur DB / WB (° C) refroidissement 32/23 43/26 maximum chauffage 27 / - 24/18 maximum REMARQUE: La plage de température de fonctionnement (température extérieure) pour le refroidissement est de 18 °C ~ 43 °C; plage de température de chauffage pour le modèle sans courroie de chauffage électrique pour le châssis est de -15 °C ~ 24 °C;...
  • Página 59: Nom Des Pièces

    Nom des pièces pièces Entrée d'air Poignée Sortie d'air REMARQUE: Le produit peut être différent de graphiques ci-dessus, s'il vous plaît se référer aux produits réels.
  • Página 60: Analyse De Dysfonctionnement

    Analyse de Dysfonctionnement Dysfonctionnement Analyse générale des défauts S'il vous plaît vérifier ci-dessous les articles avant de demander l'entretien. Si le problème ne peut toujours pas être éliminé, s'il vous plaît contacter revendeur local ou des professionnels qualifiés. Phénomène Cochez les articles Solution Panne électrique? Attendez la récupération d'énergie.
  • Página 61: Sécurité Du Fonctionnement Des Réfrigérants Inflammables

    Sécurité du fonctionnement des réfrigérants inflammables Conditions de qualification pour l'installateur et la maintenance Tous les techniciens qui se livrent dans le système de réfrigération doit porter la certification valide décerné par l'organisation faisant autorité et le qualification pour traitant du système de réfrigération reconnu par cette industrie.
  • Página 62 Sécurité du fonctionnement des réfrigérants inflammables Soudage Si vous devez couper ou souder les tuyaux du système de réfrigérant dans le processus de maintien, s'il vous plaît suivez les étapes ci-dessous: 1. Arrêtez l'unité et l'alimentation électrique coupée. 2. Éliminer le fluide frigorigène. 3.
  • Página 63: Installation

    Installation préparer Plan d'installation Tuyau de drainage Outils 1 Mètre de niveau 2 Tournevis 3 Forage d'impact 4 Tête de perçage 5 Dudgeonnière 6 Torqueclé 7 Une ouverture de la clé 8 Coupe-tube 9 Détecteur de fuite 10 La pompe à vide 12 Universal mètre 11 Appareil de mesure de pression 13 Clé...
  • Página 64: Précautions De Sécurité

    Installation préparer Unité extérieure 1. Sélectionnez un emplacement où le bruit et l'air de sortie émis par l'unité extérieure ne causent pas de gêne. 2. L'endroit doit être bien ventilé et sec, dans lequel l'unité extérieure n'est pas directement exposée au soleil ou à un vent violent. Le lieu doit pouvoir supporter le poids de l'unité...
  • Página 65 Installation préparer Exigence de mise à la terre 1. La climatisation est l'appareil électrique de première classe. Il doit être mise à la terre correctement avec un appareil de mise à la terre par un professionnel spécialisé. S'il vous plaît assurez-vous qu'il est toujours mis à la terre efficace, sinon il peut provoquer un choc électrique.
  • Página 66 Installation préparer 2. Lors de l'installation ou du déplacement de cette unité, ne chargez pas le réfrigérant qui ne correspond pas à la plaque signalétique ou un réfrigérant non qualifié. Dans le cas contraire, il peut provoquer un fonctionnement anormal, un dysfonctionnement mécanique ou même des accidents graves pour la sécurité...
  • Página 67: Installation De L'unité

    Installation de l'unité extérieure Étape 1: Fixer le support de plein air Sélectionnez en fonction de la situation réelle de l'installation 1. Sélectionnez l'emplacement d'installation en fonction de la structure de la maison. 2. Fixer le support de l'unité extérieure à l'emplacement sélectionné au moyen de vis d'expansion.
  • Página 68: Installation De L'unité Extérieure

    Installation de l'unité extérieure Étape 3: Fixer l'unité extérieure 1. Placez l'unité extérieure sur le support. 2. Fixez les trous du pied de l'unité extérieure avec des boulons. trous de pied Étape 4: Connecter tuyau intérieur et extérieur 1. Retirez la vis sur la poignée droite de 2.
  • Página 69 Installation de l'unité extérieure Étape 5: Connectez tuyau intérieur et extérieur Retirez le clip métallique; raccordez le câble de commande de fil et le signal de raccordement électrique (uniquement pour le refroidissement et le chauffage) à la borne de câblage en fonction de la couleur, fixez-les à l'aide de vis. 2.
  • Página 70 Installation de l'unité extérieure Etape 7: Pompe à vide Utilisation pompe à vide 1. Retirer les bouchons de valve sur la valve de liquide et la soupape de gaz et l'écrou d'évent de chargement de frigorigène. soupape de liquide piézomètre soupape Capuchon de gaz...
  • Página 71: Vérifiez Après L'installation

    Vérifiez après l'installation Vérifier l'accord avec l'exigence suivante après avoir terminé l'installation. Eléments à vérifier Dysfonctionnement L'unité a été installée correctement? L'unité peut tomber, trembler ou émettre du bruit. Avez-vous fait le test de fuite de Il peut provoquer un refroidissement suffisant (chauffage) capacité.
  • Página 72: La Configuration De La Connexion Du Tube

    La configuration de la connexion du tube 1. Longueur standard de tuyau de raccordement ● 5m, 7,5m, 8m. 2. Longueur minimale de la conduite de raccordement: Pour l'unité avec le tuyau de connexion standard de 5 m, il n'y a pas de limitation de la longueur min de tuyau de raccordement.
  • Página 73: Tuyau Méthode Expansion

    Tuyau méthode expansion tuyau La dilatation inadéquate des conduites est la principale cause des fuites de réfrigérant. Veuillez développer le pipeline en suivant les étapes suivantes: A: Couper le tuyau E: Élargir le port Étendre le port avec l'expandeur Confirmer la longueur de tuyau selon la distance de l'unité...
  • Página 75: Unidade Exterior

    PORTUGUÊS MANUAL DO UTILIZADOR E INSTALAÇÃO UNIDADE EXTERIOR IX90S-R32C HTWS026IX90SR32C-O | HTWS035IX90SR32C-O HTWS052IX90SR32C-O | HTWS071IX90SR32C-O...
  • Página 76 Índice Notas de operação Precauções ......................75 Nomes peças ....................... 80 Mau funcionamento Análise mau funcionamento ................81 Notas de instalação Operações de segurança de um gás inflamável ..........82 Preparação da instalação ................... 84 Instalação Instalação da unidade ..................88 Verificações após instalação ................
  • Página 77: Precauções

    Precauções Por favor leia cuidadosamente este manual de funcionamento antes de iniciar o funcionamento. Aparelho com gás inflamável R32. Antes de usar o aparelho, leia primeiro o manual de utilizador. Antes de instalar o aparelho, leia primeiro o manual de instalação. Antes de reparar o aparelho, leia primeiro o manual de serviço.
  • Página 78 Precauções ATENÇÃO Operação e Manutenção Este aparelho pode ser utilizado por crianças com idade igual ou superior a 8 anos e pessoas com capacidades físicas, sensoriais ou mentais reduzidas ou falta de experiência e conhecimentos, se tiverem recebido supervisão ou instruções relativas ao uso do aparelho de forma segura e compreenderem os perigos existentes.
  • Página 79 Precauções ATENÇÃO Não bloqueie a saída de ar ou a entrada de ar. Isso pode causar um mau funcionamento. Não deixe cair água em cima do controlo remoto, o controlo poderia danificar-se. Quando ocorrer algum dos fenómenos indicados abaixo, por favor desligue o ar condicionado, desconecte da alimentação imediatamente e entre em contacto com o distribuidor ou técnicos qualificados para o serviço.
  • Página 80 Precauções ATENÇÃO O ar condicionado deve estar devidamente ligado à terra. Uma má ligação à terra pode causar choques elétricos. Inclua um interruptor de corte com uma capacidade adequada. O interruptor deve incluir uma proteção magneto-térmica, que irá proteger contra curto-circuitos e sobrecargas. Não utilize cabo de alimentação não certificado.
  • Página 81 Precauções ATENÇÃO A resistência da terra deve estar em conformidade com as regras nacionais de segurança elétrica. O aparelho deve ser posicionado de modo que a caixa de ligações esteja acessível. Todos os fios da unidade interior e da unidade exterior devem ser conectados por um profissional.
  • Página 82: Nomes Peças

    Nomes das peças Entrada de ar Suporte Saída de ar NOTA: Produto real pode ser diferente das figuras acima, por favor consulte os produtos reais.
  • Página 83: Análise Mau Funcionamento

    Análise mau funcionamento Análise geral Por favor, verifique os itens abaixo antes de pedir assistência. Se o mau funcionamento ainda não for eliminado, entre em contato com o revendedor local ou com profissionais qualificados. Incidência Verificações Solução Falha de energia? Espere até...
  • Página 84: Notas De Instalação

    Operações de segurança de um gás inflamável Qualificações requeridas para instalação e manutenção Todos os profissionais envolvidos na instalação/manutenção devem ter a certificação válida concedida por uma entidade autorizada e a qualificação para lidar com este tipo de sistema. Se precisar de outro técnico para fazer manutenção e reparação do equipamento, este deve ser supervisionado pela pessoa que possui a qualificação para utilizar o refrigerante inflamável.
  • Página 85: Carga De Refrigerante

    Operações de segurança de um gás inflamável Soldadura Para cortar ou soldar os tubos do sistema de refrigeração no processo de manutenção, por favor siga as etapas abaixo: Desligue a unidade e remova da fonte de alimentação. Retire o refrigerante. Coloque em vácuo.
  • Página 86: Preparação Da Instalação

    Preparação da Instalação Desenho da Instalação Tubo de drenagem Ferramentas 1 Medidor de nível 2 Chave de fenda 3 Barbequim 4 Broca 5 Abocardador 6 Chave dinamométrica 7 Chave de bocas 8 Cortador de tubo 9 Detector de fugas 10 Bomba de vácuo 11 Manómetro 12 Medidor universal 14 Fita métrica...
  • Página 87 Preparação da Instalação Unidade Exterior 1. Selecione um local onde o ruído e o fluxo de saída de ar emitidos pela unidade exterior não afectem a vizinhança. 2. O local deve ser bem ventilado e seco, e a unidade exterior não deverá ser exposto diretamente à...
  • Página 88: Requisitos De Terra

    Preparação da Instalação Requisitos de terra 1. O ar condicionado é um equipamento elétrico de primeira classe. Deve ser adequadamente aterrado por um profissional com um dispositivo de aterramento especializado. Por favor, certifique-se que está sempre aterrado de forma eficaz, caso contrário, pode causar choque elétrico.
  • Página 89 Preparação da Instalação (válvula de líquido). Cerca de 30 a 40 segundos depois, feche totalmente a no lado de baixa pressão (válvula de gás), pare imediatamente a unidade e desligue a energia. Por favor, tenha em conta que o tempo para a recuperação de refrigerante não deve exceder 1 minuto.
  • Página 90: Instalação Da Unidade

    Instalação da unidade Passo 1: Fixe o suporte da unidade exterior Selecione o suporte de acordo com o tipo de situação 1. Selecione o local de instalação de acordo com a estrutura da casa. 2. Fixe o suporte da unidade exterior no local selecionado com parafusos de expansão. Notas: ●...
  • Página 91: Instalação Da Unidade Exterior

    Instalação da unidade Instalação da unidade exterior Passo 3: Fixar a unidade exterior 1.Coloque a unidade exterior no suporte. 2.Fixe os orifícios dos pés da unidade exterior com parafusos. furos para os pés Passo 4: Ligue o tubo interno e externo 2.
  • Página 92 Instalação da unidade Passo 5: Ligue o tubo interno e externo 1. Remova a proteção; Ligue o cabo de energia e o cabo de controlo de sinal (apenas para unidade de arrefecimento e aquecimento) para o terminal de bornes de acordo com a cor, fixe-os com parafusos.
  • Página 93 Instalação da unidade 3. Abra o piezômetro completamente por válvula piezômetro 15 min para verificar se a pressão do líquido gás piezômetro permanece em -0.1MPa. válvula tampa da tomada de válvula carga de 4. Feche a bomba de vácuo e mantenha refrigerante assim por 1-2min para verificar se a porca de...
  • Página 94: Verificações Após Instalação

    Verificações após instalação Verifique os seguintes requisitos após terminar a instalação. Itens a verificar Possível mau funcionamento A unidade pode cair, tremer ou emitir ruído. A unidade foi instalada com firmeza? Isso pode causar um problema na capacidade de Foi feito o teste de vazamento do arrefecimento/aquecimento refrigerante? O isolamento térmico do gasoduto é...
  • Página 95: Configuração Das Ligações Frigoríficas

    Configuração do tubo de ligação 1.Comprimento padrão do tubo de ligação 5m, 7.5m, 8m. Comprimento mínimo do tubo: Para a unidade com tubo de ligação padrão de 5m, não há limitação para o comprimento do tubo. Para a unidade com tubo de ligação padrão de 7,5m e 8m, o comprimento mínimo do tubo é...
  • Página 96: Método De Expansão De Tubos

    Método de expansão de tubos Abocardo inadequado do tubo é a principal causa de fuga de refrigerante. Por favor, expanda o tubo de acordo com os seguintes passos: A: Corte o tubo E: Espanda a porta Expanda a porta com o expansor. Confirme o comprimento do tubo de acordo com a distância entre a unidade interior e a unidade exterior.
  • Página 100 FRANCE PORTUGAL ITALIA [email protected] [email protected] [email protected] ADVERTENCIAS PARA LA ELIMINACIÓN CORRECTA DEL PRODUCTO SEGÚN ESTABLECE LA DIRECTIVA EUROPEA 2002/96/EC. establecidos por las administraciones municipales, o a los revendedores que facilitan este servicio. Eliminar por separado un aparato eléctrico o permite reciclar los materiales que lo componen, obteniendo así un ahorro importante de energía y recursos. Para subrayar la obligación de eliminar por separado el aparato, en el producto aparece un contenedor de basura móvil listado.