Page 6
Safety Information
Please read the following carefully before installing and connecting the
system to a power source.
Note:
Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS
3260) should install, replace, or service the equipment. Install the system in accordance
with Country, National, or the U.S. National Electric Code if you are in the United
States.
Precautions
1. The building where this product is used requires a fuse or circuit
breaker no larger than 15 A for 120 VAC (U.S.A.) or 10 A, 230 VAC
(international). The building facility must protect the AXIS PoE
Midspans 8P/16P from over current or short-circuits.
2. Read the Midspan Hardware Setup procedure before connecting
the AXIS PoE Midspans 8P/16P to a power source (including
power cord requirements).
3. Do not operate the product in an area that exceeds the maximum
recommended ambient temperature of 104 ºF/ 40 ºC to avoid
overheating the AXIS PoE Midspans 8P/16P. Allow at least 3 to 4
inches/ 7.6 to 10.2 cm clearance around all ventilation openings.
4. Do not stack the chassis on any other equipment to support its
weight. Shelf mounted equipment requires a stable and durable
surface. Do not push or pull on the Midspan while installing.
5. The AXIS PoE Midspans 8P/16P consists of two rows of "Data"
and "Data & Power" ports. The ports use RJ-45 data sockets.
Connect only RJ-45 data cables to these sockets. Do not connect
telephone cables into these ports.
6. Do not work on the AXIS PoE Midspans 8P/16P system or connect
or disconnect cables, when there is lightning.
7. The AC or DC plug/socket combination must be accessible at all
times, as it is the main disconnect device to the product.
Safety Information