Troubleshooting - Krups XP1500 Instrucciones De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3.Dissolve a packet of Krups descaling
solution in 10 oz / 300 ml of lukewarm
water and pour into the boiler container. Put
one receptacle under the brewing head and
another under the steam nozzle.
(Note : Do not use the filter holder during
decalcification.)
4.Open the steam valve and turn on the
appliance. Allow the descaling solution to
run out of the espresso outlet and the steam
nozzle.
5.After each brewing cycle, switch off the
appliance and allow the appliance to cool
down.
6.Repeat this operation once again.
Following this, allow 2 boiler container of
clear water to run through the system. Switch
off the appliance. Allow the appliance to cool
down. Insert the brewing sieve into the
brewing head again and push the plastic
housing of the cappuccino nozzle onto the
steam nozzle.

Troubleshooting

(Always check if the appliance is plugged
in and is in the proper (on) position).
Problem :
1. Espresso leaking from filter holder.
Cause :
Filter holder not properly inserted.
Filter holder not pushed in far enough.
Internal gasket is dirty and needs to be
cleaned.
Gasket without elasticity, replace it with a
new one.
Coffee powder not cleaned off the edge of
the filter holder.
Problem :
2. Espresso does not come out.
Cause :
No water in boiler container.
No coffee in filter holder.
Filter clogged because coffee ground is too
fine and or pressed down too hard
16
Problem :
3. Steam does not come out of steam nozzle.
Cause :
No water or not enough water in the boiler
chamber.
Steam nozzle is clogged (see «Cleaning
the cappuccino nozzle » section).
Problem :
4. Not enough froth when frothing the milk.
Cause :
Steam nozzle touches the bottom of
the pitcher.
Steam nozzle is clogged : tiny holes on top
of plastic housing of the cappuccino nozzle
are clogged (see «cleaning the cappuccino
nozzle»)
Milk is not fat enough or too warm (more
than 8°C).
For best results .....
....Always use fresh, cold water (warm water
might be stale and have mineral deposits
which would impair the flavor of the coffee)
... We recommend that you grind your own
beans. Freshly ground beans deliver more
aroma and flavor. Use one KRUPS measuring
scoop of beans per cup.
....Serve coffee immediately after brewing.
....Never reheat coffee.
Accessory
Optional accessory, sold separatly : Duo Filter
ref F15A04.
Anti chlorine and anti-scale filter optimizes
coffee taste and reduces the frequency of
descaling and maintenance.