Troubleshooting; Safety Notices; Cause And Action - Caso VC150 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 98
Preservation bags
Washing the bagging material in warm water with a mild dishwashing soap, then rinse the
bags well and allow drying thoroughly before reusing
Attention
► Bags used to store raw meats, fish or greasy foods can't be reused.
Vacuum interface:
Unbag the airproof loop of sponge from the interface and put it into warm and soapy water
for safe washing.
Please note
► The airproof loop of sponge should be dried thoroughly prior to reassembling.
► When re-assembling, be careful to prevent any damage and assembles as original
position to ensure no vacuum leaking.

16 Troubleshooting

This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:

16.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.

16.2 Cause and Action

In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.
Error
Vacuum unit is not
functioning
The first weld on the cut
off piece of the roll is not
being carried out.
caso Vakuumierer VC150
Possible cause
Power plug is not plugged in Plug in mains plug!
Defective power cable or
plug
Defective electrical socket
Roll is not positioned
correctly
.
Rectification
Send device to Customer
Service
Select another electrical socket
Follow the steps in the chapter
"making a bag using the bag roll"
42