schmalz SCTMi Instrucciones De Funcionamiento página 43

Ocultar thumbs Ver también para SCTMi:
Tabla de contenido
Extended Device Status Event Category
Parameter
138 (0x008A)
Description
Extended Device Status - Event Category
Index
1: Event Category of current device status
Datatyp
uint16
Length
1 Byte
Access
read only
Value range
0x10: Device is operation properly
0x21: Warning, low
0x22: Warning, high
0x41: Critical condition, low
0x42: Critical condition, high
0x81: Defect/fault, low
0x82: Defect/fault, high
Default value
-
Unit
-
EEPROM
no
Extended Device Status – Event code
Parameter
138 (0x008A)
Descrip-
Extended Device Status – Event code
tion
Index
2: Event Category of current device status
Datatyp
uint16
Length
1 Byte
Access
read only
Value ran-
Eventcode
ge
0x5100
0x5110
0x5112
0x1812
0x1802
0x1811
0x1000
0x8C01
0x180C
0x180D
0x180E
0x8C20...8C2F
0x8D00...8D0F
0x8D10...8D1F
0x8D20...8D2F
0x8D30...8D3F
0x8D40...8D4F
0x8D50...8D5F
ES · 30.30.01.01598 · 02 · 01/19
Eventname
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Input pressure too high (>6,3 bar) or too low
(<1, 9bar)
Internal error, user data corrupted
Internal error, Bus fault
Manual mode is active in at least one ejector
Condition Monitoring: primary supply voltage
US outside of operating range
Condition Monitoring: secondary supply volta-
ge outside of operating range
Condition Monitoring: supply pressure outside
of operating range (3,5 ... 5 bar)
Calibration fail, Ejector #1...#16
Measurement range overrun, Ejector #1...#16
Valve protection active, Ejector #1...#16
Evacuation time t1 is greater than limit, Ejec-
tor #1...#16
Leakage rate is greater than limit, Ejector #1...
#16
H1 was not reached, Ejector #1...#16
Free-flow vacuum level too high, Ejector #1...
#16
Interfaces
Status Category
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Defect/fault, high
Defect/fault, high
Warning, low
Warning, high
Warning, high
Warning, high
Defect/fault, low
Defect/fault, low
Warning, high
Warning, low
Warning, low
Warning, high
Warning, low
43 / 72
Tabla de contenido
loading

Este manual también es adecuado para:

ScpstProfinetEthernet/ipEthercat

Tabla de contenido