Characteristics
• single thermostat with possibility of temperature management in adjustable
range (it is possible to modify this range or make a special one on request)
• it is used to regulate heating (or cooling) in demanding environments (outside,
humidity, dustiness, etc.)
• thermostat is placed in water-proof box with IP65, which enables installation
outside, with in-built sensor (included in the supply)
• TEV-2 - control and indication elements are placed under transparent cover,
TEV-3 - control and indication elements are placed directly on the cover (for easy
orientation and frequent change of temperature)
• thermostat status is indicated by LED (2 colours)
• function of monitoring sensor disconnection and short-circuit
• output changeover contact 16 A (AC1)
Description
TEV-2 - without cover
4
5
1. Device status indication
2. Temperature setting
3. Terminal for sensor
4. Terminals for connection of supply voltage and output contact
5. Sleeve for incoming cables
6. Sensor TZ-0
7. Sensor TC-0
cos φ ≥ 0.95
Type of load
AC1
Mat. contacts AgNi,
contact 16 A
250V / 16A
Type of load
AC13
Mat. contacts AgNi,
contact 16 A
250V / 6A
TEV-3 - cover
1
2
3
5
6
M
M
AC2
AC3
250V / 5A
250V / 3A
K
AC14
AC15
250V / 6A
250V / 6A
TEV-2
TEV-3
Thermostat
Symbol
Connection
Function heating
1
2
Function cooling
7
AC5a
AC5a
uncompensated
compensated
x
230V / 3A (690VA)
M
DC3
DC1
24V / 6A
24V / 16A
1 / 2
L
T
°C
T
N
V2 V1
HAL.230V
AC5b
AC6a
800W
x
250V / 3A
M
DC5
DC12
24V / 4A
24V / 16A
EN
AC7b
AC12
250V / 10A
DC13
DC14
24V / 2A
24V / 2A