Ex-Data; Atex; Iecex; Nec & Cec - Ecom Tab-EX 02 DZ2 Instrucciones De Seguridad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99

5. Ex-Data

5.1 ATEX

ATEX Certificate of Conformity no.: EPS 18 ATEX 1 055 X
Relevant Standards: EN 60079-0:2012/A11:2013
Ex-Marking:
Ambient temperature: -20 °C ≤ Ta ≤ +55 °C
Approved for zone 2, device group II, explosion group IIC (explosive gases, vapors or
mist), temperature class T5. Approved for zone 22, device group II, explosion group IIIB
(combustible flying, non-conductive dust), maximum Temperature 100°C.

5.2 IECEx

IECEx Certificate of Conformity no.: IECEx EPS 18.0029X
Relevant Standards: IEC 60079-0:2017 ed.7
Ex-Marking:
Ambient temperature: -20 °C ≤ Ta ≤ +55 °C
Approved for zone 2, device group II, explosion group IIC (explosive gases, vapors or
mist), temperature class T5. Approved for zone 22, device group II, explosion group IIIB
(combustible flying, non-conductive dust), maximum Temperature 100°C.
5.3 NEC & CEC
Ex-Marking:
248090
Ambient temperature: -20 °C ≤ Ta ≤ +55 °C
Approved for Division 2 / Zone 2, Class I.
EN 60079-11:2012
† II 3G Ex ic IIC T5 Gc
† II 3D Ex ic IIIB T100°C Dc
IEC 60079-11:2011 ed.6
Ex ic IIC T5 Gc
Ex ic IIIB T100°C Dc
NI CL I DIV 2 GRP A-D T5
Class I Zone 2 Group IIC T5
5
loading