Instructions d'installation pour module MA4MR IRiS Installation Instructions – Module MA4MR
rotating counter clockwise. Pivot screwdriver to achieve
desired beam angle (Figure18.) and tighten screw. To rotate
mechanism, loosen clamping screw (Figure19.). Insert
screwdriver into rotation tab and rotate assembly to desired
position. Retighten clamping screw.
Elementse:
Installation of element into housing platform is performed
after the housing platform is installed in the ceiling, the
module is installed in housing platform and the aperture
opening has been cut into the ceiling. Refer to the
Installation Instruction sheet for the element being used for
proper installation and lamping instructions.
Top Access and Re-Lampinge:
Top access is obtained by loosening the top access thumb
screw on the housing platform and pivoting the top open.
This will allow for inspecting and servicing the fixture
without removal. In addition to normal re-lamping from
below the ceiling, the P406TAT and P408ICAT housing
platforms can be re-lamped using top access. A minimum of
10" clearance above the housing is recommended to allow
top access. The installer must insure proper clearance for
access to the fixture.