GEA ZET1P Instrucciones De Instalación página 3

Hornos de pared eléctricos empotrados
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2 C
CUTOUT FOR DOUBLE OVENS (2 THERMAL OVENS)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
E
Dim.
Description
27" Double Oven
A
Cabinet Width
27" (68.6 cm)
B
Cutout Width
25" (63.5 cm) min.
25
" (64.1 cm) max.
1 4
C
Cutout Height
49
" (126.2 cm) min.
11 16
50
" (127.3 cm) max.
1 8
D
Overlap of Oven
1" (2.5 cm)
Over Side Edges
of Cutout
E
Clearance to
23" (50.8 cm) min.
Adjacent Corners,
Drawers, Walls, etc.,
When Door Is Open
F
Overlap of Oven
1" (2.5 cm) min.
Top of Cutout
G
Overlap of Oven
1" (2.5 cm) min.
Bottom of Cutout
H
Junction Box
8
" (22.2 cm) max.
3 4
Location
right side only
J
Height to Bottom
44" (111.8 cm)
of Junction Box
K
Recommended
13
1 4
" (33.7 cm)
Cutout Location
from Floor
Continue to Section 3.
31-11043 08-16 GEA
H
B
Junction
Box
Location
(junction
box may
be located
in adjacent
cabinet)
F
D
J
G
Cutout Depth
23-1/2"
(59.7 cm) Min.
A
30" Double Oven with
30" Double Oven
Pedestal
without Pedestal
30" (76.2 cm)
30" (76.2 cm)
28
" (72.4 cm) min.
28
" (72.4 cm) min.
1 2
1 2
28
" (72.7 cm) max.
28
" (72.7 cm) max.
5 8
5 8
51
" (131.6 cm) min.
13 16
50 ¼" (127.64cm)
51
15 16
" (131.9 cm) max.
" (1.75 cm)
11 16
11 16
23" (53.3 cm) min.
23" (53.3 cm) min.
1" (2.5 cm) min.
1" (2.5 cm) min.
(1
" (3.2 cm) for PT9550,
(1
" (3.2 cm) for PT9550,
1 4
1 4
ZET2S and ZET2P)
ZET2S and ZET2P)
1
" (3.2 cm)
1
1 4
9
" (24.1 cm) max.
9
" (24.1 cm) max.
1 2
1 2
right side only
right side only
47" (119.4 cm)
47" (119.4 cm)
12" (30.5 cm)
12" (30.5 cm)
2 D
CUTOUT FOR INSTALLATION OVER A WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single or double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with
the Warming Drawer for specific installation requirements.
C
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
K
" (1.75 cm)
Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.
" (3.2 cm)
1 4
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Tabla de contenido
loading

Este manual también es adecuado para:

Zet1sZet9050Zet2pZet2sZet9550Zek7000 ... Mostrar todo

Tabla de contenido