Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

The Upholstery Pro cleaning tool provides deep, rapid penetration of cleaning solution and
simultaneous high volume extraction. Lightweight, easy to use, and adjustable for a wide range of
fabrics and soiling conditions, the Upholstery Pro produces cleaner, drier fabrics.
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
KEY FEATURES
 Comfortable handle and highly flexible vacuum hose
provides relaxed balanced handling and substantially
reduces operator fatigue.
 In-line solution strainer helps prevent clogging.
 High pressure injector glide provides deep, even
penetration of solution into fabric surface.
 Unique dual extraction slots permit full extraction in
both directions across fabric surfaces
 Sliding vacuum release allows for precise vacuum
control on delicate fabrics.
 Clear housing for easy monitoring of water flow, fabric
or carpet dryness, and cleaning effectiveness.
USING THE UPHOLSTERY PRO
1. Connect the rear quick-connect solution line to the
extractor solution line
2. Attach the rear hose coupling to the extractor vacuum
port.
3. Turn on extractor.
4. Squeeze the trigger lever to release the solution and
begin cleaning. The sliding trigger lock may be used
to hold the trigger valve in the open position.
FIG. A: HEAD, VACUUM HOSE AND
SOLUTION LINE ASSEMBLY
Vacuum
release slide
07-02087B F436-P
User Instructions
Upholstery Pro
Model F436-P
Patents: http://www.LBpatents.com
Solution line
quick-connect
coupling. See
Fig. D for
parts detail.
Rear vacuum hose cuff.
Solution trigger lever.
5. Use the vacuum release slide (Fig. A to adjust the
strength of the vacuum as needed.
WARNING: Quick-connect coupling
can become extremely hot during
use.
Tips for Use
Vacuum control. Use the vacuum release slide (Fig. A)
to control the strength of the vacuum when extracting
thin, delicate or lightweight fabrics.
For best results, use the Upholstery Pro with Legend
Brands cleaning chemicals.
For more information about cleaning with the Upholstery
Tool, visit LegendBrandsCleaning.com.
MAINTENANCE
Daily: Rinse the hand tool by running clean water
through the solution line.
Daily: Check the glide assembly (Fig. A) for steady,
even flow of solution through the injector nozzles. If any
of the injector ports appear clogged, use a small needle
to remove the obstruction, taking care not to damage the
glide. If the glide is scratched, gouged, snags on
carpets, or flows excessively, it may need to be
replaced (see "Servicing the glide," below).
Replacement glide assemblies are available from
your distributor.
As needed: Lubricate the quick-connect
couplings (Fig. A) with a small amount of rust-
inhibiting oil such as LPS-3.
As needed: Lubricate trigger valve stem (Fig.
C) with a small amount of synthetic heavy duty
grease. To grease the stem, follow these steps.
1. Remove the trigger lever nut and bolt from the
trigger lever and remove lever.
2. Unscrew stem retention nut and lift out stem
assembly. Apply a small amount of grease to the
stem.
1
Sapphire Scientific
Tabla de contenido
loading

Resumen de contenidos para Sapphire Scientific Upholstery Pro F436-P

  • Página 1 1. Remove the trigger lever nut and bolt from the trigger lever and remove lever. Solution trigger lever. 2. Unscrew stem retention nut and lift out stem assembly. Apply a small amount of grease to the stem. 07-02087B F436-P Sapphire Scientific...
  • Página 2 If replacement becomes tube and pull out the tube. Avoid kinking the tube. necessary, rebuild kits and replacement parts are available from your Sapphire distributor or from Sapphire Scientific at 800-932-3030. FIG. D: SOLUTION LINE COUPLING ASSEMBLY Replacing the glide Rear quick-...
  • Página 3: Replacement Parts

    03-01649 as to contact you in case we have important safety Orifice Fig. D 03-01903 information concerning your Sapphire Scientific product. Nylon washer Fig. D 03-01652 If you determine service is required, have your equipment model, serial number and original proof of...
  • Página 4: Características Principales

    Vaya engancha en las alfombras o expulsa la solución Regulador de a la Fig. D disparo de para ver las aspiración Boquilla de manguera partes en de aspiración trasera detalle. Palanca del gatillo de solución 07-02087B F436-P Sapphire Scientific...
  • Página 5: Servicios Para El Mantenimiento

    Sapphire o llamando al número de excesivamente, es posible que necesite reemplazarlo teléfono de Sapphire Scientific: 800-932-3030. (lea la próxima sección “Sustitución del deslizante”). Los repuestos del ensamblaje del deslizante se encuentran Sustitución de la barra deslizante...
  • Página 6: Piezas De Repuesto

    Sapphire Scientific. Si se requiere servicio, ensamblaje de la manguera de entrada. tenga a su disposición el modelo de su equipo, el 7.
  • Página 7: Caractéristiques Principales

    (Figure A) pour obtenir un débit constant et stable de solution à travers les buses de Levier de déclenchement de l’injecteur. Si toute sortie de l’injecteur semble la solution bouchée, utiliser une petite aiguille pour retirer 07-02087B F436-P Sapphire Scientific...
  • Página 8 Couvercle inférieur quelques minutes. Si le remplacement devient nécessaire, des ensembles de réparation et des pièces de rechange sont disponibles auprès de votre distributeur Sapphire ou de Sapphire Scientific au (800)932-3030. Vis du patin Corps de la vanne (×4) Remplacement du patin (à...
  • Página 9: Pièces De Rechange

    6. Insérer le nouvel ensemble de vanne de vous en cas de consignes de sécurité importantes déclenchement et rebrancher le tube de sortie de la concernant votre produit Sapphire Scientific. Si vous solution ainsi que l’ensemble du tuyau d’arrivée de déterminez que des réparations sont nécessaires, ayez la solution.

Tabla de contenido