Positioning Of The Outdoor Unit For The S 39Xx And Sc 39Xx - Qlima S 3925 Manual De Instalación

Ocultar thumbs Ver también para S 3925:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
the ceiling. See Picture 4
The indoor unit must be mounted level.
Consider de possible positions of the outdoor unit when positioning the indoor unit. The piping and
cables of indoor and outdoor unit have to be connected.
G
ATTENTION
For SC 39xx models: The length of the pipe is 4 meter.
For S 39xx models: The maximum length of the piping between the indoor and outdoor unit is 15
5.2 Positioning of the outdoor unit for the S 39xx and SC 39xx models
Position the outdoor unit on a firm foundation to minimalize unwanted noise and vibration.
G
NOTE
The outdoor unit makes noise when the unit is in service; this can be in conflict with
local legislation and regulations. The user is responsible to check this and to make sure the
equipment fully complies with the local legislation.
Choose the direction of the air outlet so the exhaust air is not obstructed.
Consider the weight of the indoor and outdoor unit.
If a shelter will be build to avoid that the outdoor unit is exposed to direct sunlight or rain, it has to
be made sure that the condenser isn't obstructed.
Make sure there is at least 30 cm free space around the back and on the left. The free space at the
front of the unit has to be at least 200 cm and a free space of 60 cm has to be maintained at the
connection side (right side). (See Picture 5.)
The outdoor unit has to be positioned level.
meters.
The maximum height difference between the indoor and outdoor unit is 5
meters.
Picture 4
Picture 5
4
49
Tabla de contenido
loading

Este manual también es adecuado para:

Sc 3925S 3932Sc 3932S 3948Sc 3948

Tabla de contenido