GB
5.3 In case of work in the home
The detector must not be painted.
If work is to be carried out after the detector has been installed, cover it completely.
IMPORTANT: do not forget to remove the protection when the work is finished.
6. Technical data
• Type of detection: optical smoke detector and heat detector
• Average coverage: 50 m
2
• Use: indoor
• Power: sealed, non-replaceable lithium battery 2 x 3 V with a 10-year battery life
• Indication: - detector status
- faults
• Integrated sounding upon detection: 85 dB at 3 m
• 75 dB integrated sounding at 1 m: - during testing
- during fault indications
• Interconnection via radio: 10 detectors max.
• Operating temperature: -10°C to + 65°C
• Storage temperature: -10°C to + 65°C
• Degree of protection: IP22
• Dimensions (D x H): 127 mm x 49 mm
• Weight: 255 g
117