2 Pin Red Connector : HI-JACK OVERRIDE
Route the 2 pin red connector from the override switch previously mounted to the mating two pin connector
on the module.
Red & Green 2 Pin White Connector : DOOR LOCK OUTPUTS
These wires will provide a pulsed ground output to the factory door lock control relay. The maximum current
draw through these outputs must not exceed 300 mA.
3 Wire Ground Switched Door Locks
In this application, the red wire provides a ground pulse during arming, or the pulsed ground lock output.
Connect the red wire to the wire that provides a low current ground signal from the factory door lock switch
to the factory door lock control relay.
The green wire provides a ground pulse during disarming, or the pulsed ground unlock output. Connect
the green wire to the wire that provides a low current ground signal from the factory door unlock switch to
the factory door lock control relay.
3 Wire Positive Switched Door Locks
4 Wire Polarity Reversal and
5 Wire Alternating 12 Volt
Door Lock Control Circuits
In these applications, the AS 9159 Door Lock Interface ( or equivalent 30 A automotive relays ) must be
used. Refer to the AUDIOVOX Door Lock Wiring Supplement for proper connection to these types of
circuits.

COMPLETING THE INSTALLATION

Antenna Wire : Be sure to extend the thin black antenna wire to it's full length, and cable tie into place
where it cannot be damaged. Avoid wrapping this wire around major, high current wire looms.
Adjusting the Shock Sensor :
Be certain to adjust the shock sensor according to the manual packaged with the sensor.
Wire Dressing : Always wrap the alarm wires in convoluted tubing, or with a spiral wrap of electrical tape.
Secure these looms along the routing using cable ties. This will ensure that the alarm wires are not
damaged by falling onto hot or sharp moving surfaces in the vehicle.
Operation : Take a few moments to check off the appropriate option boxes in the owner's manual, and to
fully explain the operation of the system to your customer.
MODULE UPGRADE CONNECTOR
The 4 pin connector marked, on the wiring diagram, for upgrade tracking module is designed to interface
only with Audiovox upgrade modules. The connector provides data 5 volt reference voltage. The specific
upgrade module has it's own instructions describing the required voltages and how it is to connect to the
host module. Please refer to the instructions packaged with your upgrade module before making any
connections to this port.
NOTE: The unit must be hardwired for trigger method, feature # 6, voltage sense turned off or the unit will
false trigger when the upgrade module activates. Pin assignments for the connector are, Pin1 = +
5 Volts, Pin 2 = Ground, Pin 3 = Data Tx, & Pin 4 = Data Rx.
ADDITIONAL PROGRAMMING INFORMATION
The receiver for the APS-25HJLAD has four receiver channels which can be operated with the remote
transmitter. Receiver channel 1 operates the arming/locking, disarming/unlocking, as well as the panic
feature of the system. Receiver channel 2 operates the channel two outputs (Dark Blue & Blue/Black)
wires of the control module. Receiver channel 3 operates the channel two output (Green/Black) wire of the
control module. Receiver channel 4, when programmed, operates the Anti HiJack feature of the system.
Channel 4, Hijack activation can be operated from the programmed transmitter regardless of the feature
selection of the control module. Please see transmitter programming information found in the
APS-95BT3LA or APS-95BT2LA or APS-95BT2VE programming guides.