EXPLOSION HAZARD—This light fixture is not backward compatible
with older products. Do not use this light fixture with the Series A ver-
sions of model CMXC, CMXC-R, PMXC, PMXC-R, WMXC, or WMXC-R
mounting accessories. Failure to follow this warning may result in per-
sonal injury or death.
II.
UNPACKING
EXPLOSION HAZARD — Damaged glass domes can lead to explo-
sions, which could result in serious injury or death. Replace dam-
aged domes.
After unpacking the unit, examine it for damage that may have occurred in tran-
sit. If the equipment has been damaged, do not attempt to install or operate the unit.
File a claim immediately with the carrier, stating the extent of damage. Carefully check
all envelopes, shipping labels and tags before removing or destroying them.
III.
INSTALLATION
The glass dome is part of the explosion proof housing. In applications
where the dome requires added protection, a separately purchased
metal guard (Part No. DGXC-SB) can be readily attached.
Recommended mounting position of this light is in a vertical orienta-
tion with the dome facing down. The pendant mount has provisions for
mounting to 3/4" pipe.
The instructions below are for lights using the pendant mount option (PMXC-SB).
Refer to instruction manual 25500050 for the ceiling mount (CMXC-SB) or wall mount
option (WMXC-SB).
Wiring must comply with the National Electrical Code or Canadian Electrical
Code and the local authority having jurisdiction
For marine applications, all wiring (including supply wire) must be stranded wire
and meet the USCG (CFR46) Section (110-113).
The Model 27XST strobe light should be installed per the NEC or CEC, STATE
and LOCAL CODES. Alternate installation locations and/or orientations should only be
performed with the approval of the authority having jurisdiction. In addition, they can
be mounted using an optional ceiling mount or an optional wall mount.
To install the 27XST on 3/4" N.P.T. threaded pipe:
A.
Ensure that the mating threads are clean. Thread the pendant mount onto
the 3/4" pipe and secure with the set screw (see Figure 1).
B.
Remove the terminal block from the pendant mount by loosening the two
mount screws.
NOTE