Setup; Ac Power; Ac Plug; Fuse Replacement - Chauvet Professional LX Go Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Setup

AC Power

AC Plug

Fuse Replacement

LX Go™ User Manual Rev. 4
Each LX Go™ has an auto-ranging power supply that works with an input voltage range
of 100~240 VAC, 50/60 Hz. To determine the power requirements for each LX Go™,
refer to the label affixed to the product. You can also refer to the
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation.
For more information, you may download Sizing Circuit Breakers from the CHAUVET®
website: www.chauvetpro.com.
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
The LX Go™ comes with a power input cord terminated with an IEC connector on one
end and an Edison plug on the other end (U.S. market). If the power input cord that
came with your product has no plug or you need to change the Edison plug, use the
table below as a guide to wire the new plug.
Connection
AC Live
AC Neutral
AC Ground
Make sure to disconnect the product's power cord before replacing a blown fuse.
Always replace with a fuse of the same type and rating.
1. Disconnect the product from the power outlet.
2. Using a flat-head screwdriver, wedge the tip into the slot of the fuse holder.
3. Pry the safety cap out of the housing to pull out the installed fuse.
4. Remove the blown fuse from the safety cap and replace with a fuse of the exact
same type and rating (T 500mA, 250 V).
5. Insert the fuse holder back in place and reconnect the power.
Spare fuse
(inside safety cap)
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Green/Yellow
Technical Specifications
Screw Color
Brown
Yellow or Brass
Blue
Silver
Green
Installed fuse
(held by plastic clip)
Safety cap
Setup
-5-
Tabla de contenido
loading

Tabla de contenido