g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows, when
selecting "Yes", to exit the programming menu
and to take over (store) the new values.
If "no" is selected, the programming routine is
repeated, the latest values set remaining
active. They can now be checked again or
modified.
Electronic display counter with
2 totalising ranges
1. Description
• 6-digit dislay counter with Reset function
• Red LED display, character height 8 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
2. Inputs
INP A
Dynamic count input Counter A
INP B
Dynamic count input Counter B
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can be
adjusted individually for Counter A and Counter B.
The values of the A or B counter can only be
reset while they are displayed. To that purpose,
they must be released in Reset Mode.
2
3. Selection of the displayed value
Pressing the right key displays successively the
following various values:
Pressing the key once displays the current func-
tion for 1 s. Pressing the key a second time dur-
ing this period of time switches the counter to
the next function ; the counter displays the con-
firmation of the new function
for 1 s.
Then, the counter displays value of the new
selected function.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to
the factory settings
Value of counter A
Value of counter B
Difference A-B
Sum A+B
Quotient A/B
Percentage (A-B)/A