Flash Pattern Selection:
The flash pattern can be selected by powering the individual flash pattern mode and holding the blue wire to the black wire.
- A quick tap will increment by one pattern.
- 1-3 seconds to go to the previous pattern
- 3-5 seconds to return to the factory default pattern
- 5+ seconds to set to the last flash pattern
Synchronization:
The directional is capable of syncing with other compatible ECCO products by setting the desired flash pattern on each unit individually. It is also
strongly recommended that the same rate and style of flash pattern be used on all synced units to produce the most effective warning pattern.
NOTE: To operate sumultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units must be set to have the
opposite phase (A + B or B + A). Then, connect the yellow sync wires together and check that the units are flashing in a synchronized manner as
expected. If a pattern on one unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until
the correct pattern is selected.
NOTE: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.
Pattern
Description
1
Single Flash
2
Single Flash
3
Single Flash - Wig Wag
4
Single Flash
5
Single Flash
6
Single Flash - Wig Wag
7
Double Flash
8
Double Flash
9
Double Flash - Wig Wag
10
Double Flash
11
Double Flash
12
Double Flash - Wig Wag
13
Quad Flash (Default)
14
Quad Flash
15
Quad Flash - Wig Wag
16
Quad Flash
17
Quad Flash
18
Quad Flash - Wig Wag
19
Triple Flash
20
Triple Flash
21
Triple Flash - Wig Wag
22
Quint Flash
23
Quint Flash
24
Quint Flash - Wig Wag
25
Steady Burn, Single Flash - Split
26
Steady Burn
27
Modulation
28
Double, Triple Flash - Wig Wag
29
Single, Quad Flash - Wig Wag
SAE J595
FPM
Sync Phase
A
B
75
Y
A
Class 1 Class 1 Class 1 Class 1 Class B Class B Class B Class 1
75
Y
B
Class 1 Class 1 Class 1 Class 1 Class B Class B Class B Class 1
75
Y
-
-
120
Y
A
Class 1 Class 1 Class 1 Class 1
120
Y
B
Class 1 Class 1 Class 1 Class 1
120
Y
-
-
75
Y
A
Class 1 Class 1 Class 1 Class 1
75
Y
B
Class 1 Class 1 Class 1 Class 1
75
Y
-
-
120
Y
A
Class 1 Class 1 Class 1 Class 1
120
Y
B
Class 1 Class 1 Class 1 Class 1
120
Y
-
-
75
Y
A
Class 1 Class 1 Class 1 Class 2
75
Y
B
Class 1 Class 1 Class 1 Class 2
75
Y
-
-
150
Y
A
Class 1 Class 1 Class 1 Class 2
150
Y
B
Class 1 Class 1 Class 1 Class 2
150
Y
-
-
75
Y
A
Class 1 Class 1 Class 1 Class 1
75
Y
B
Class 1 Class 1 Class 1 Class 1
75
Y
-
-
150
Y
A
Class 1 Class 1 Class 1 Class 2
150
Y
B
Class 1 Class 1 Class 1 Class 2
150
Y
-
-
N
-
-
N
-
-
N
-
-
N
-
-
N
-
-
ED3777X Flash Pattern Chart
CA T13
R
W
A
B
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SAE J845
R
A
1 (
4
0
) °
B
1 (
4
0
) °
R
1 (
4
0
) °
W
1 (
Class 1
Class 1
Class 1
Class 1
Class 1
Class 1
-
-
-
-
-
Class 1
Class 1
Class 1
Class 1
-
Class 1
Class 1
Class 1
Class 1
-
-
-
-
-
Class 1
Class 1
Class 1
Class 1
-
Class 1
Class 1
Class 1
Class 1
-
-
-
-
-
Class 1
Class 1
Class 1
Class 1
-
Class 1
Class 1
Class 1
Class 1
-
-
-
-
-
Class 1
Class 1
Class 1
Class 2
-
Class 1
Class 1
Class 1
Class 2
-
-
-
-
-
Class 2
Class 2
Class 1
Class 2
-
Class 2
Class 2
Class 1
Class 2
-
-
-
-
-
Class 1
Class 1
Class 1
Class 1
-
Class 1
Class 1
Class 1
Class 1
-
-
-
-
-
Class 2
Class 2
Class 1
Class 2
-
Class 2
Class 2
Class 1
Class 2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ECE R65
0
0
) °
A
B
R
-
-
-
-
-
-
-
-
-
-
Class 1 Class 1 Class 1
Class 1 Class 1 Class 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Class 1 Class 1 Class 1
Class 1 Class 1 Class 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Page 4 of 6