Reassembly
Refit the lid of the case, ensuring that the aerial cord is firmly gripped in the guides pro-
vided and the sealing "O" ring is correctly seated.
Replace the cross-headed screws into the holes and firmly screw the case together. It is
essential that the screws are tightly secured as the water resistance is dependant on this. If
necessary, re-seal the aerial entry/exit point, with DOW-CORNING sealant REF:RTV 3145.
ON NO ACCOUNT USE AN ACETIC ACID BASED SEALANT.
(Acetic acid sealants have a vinegar-like smell.)
Clip option
An optional clip (part no. 04630EUR) is available, this clip enables the transmitter to be
clipped to clothing and so avoid the possibility of falling into liquids or food. The clip uses a
longer screw than the normal case screw but uses the same fixing holes.
Testing
Determine the limits of the transmitter's range and inform the user of these limits. Check
that the unit will function in all areas where the user EXPECTS it to function and point out
any discrepancies.