Thermostat Setting - Extraflame Can-Temp Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

thermostat setting

settings
economy: the system controls based on the the "temperature economy" points set in the menu. The
activation of this mode is indicated by the
changed using buttons on the display, they can only be changed using the settings menu.
activation/deactivation: long press buttons 1+2
language: The menu display language can be selected.
hysteresis: The hysteresis levels for relay activation can be selected, i.e. the difference between the set
temperature value and the actual activation and deactivation temperature of the relay. Correct hysteresis
settings avoid the continual ignition and switch off of the unit, units with high thermal inertia require a low
hysteresis value, where as low thermal inertia units require a high hysteresis value.
calibration: The temperature set by the thermostat can be corrected using this function.
temp unit: Set the temperature measuring unit displayed.
radio id: Configure thermostat radio transmission.
temperature eco
language
hysteresis
caliBration
temp unit
radio id
icon. The set points, with this function activated, cannot be
27
6° - 40°C
Italian-english-French-German-Spanish
0.5 - 10°C
XX°C
Celsius °C / Fahrenheit °F
XX#