Installation Instructions
1A
1
(X) x 4
(W) X 4
5
1/2" (12.7mm)
concrete
wall
(X)
(W)
(A)
wall
covering
(iCLPFM shown)
X4
2
3
x4
(A)
4
(Y) x 4
(A)
Pilot Hole -
5/16 x 3 1/4"
(M8 x 82.5mm)
(Y)
Anchor
flush with
concrete
wall
INSTALL WALL PLATE TO WALL -
CONCRETE OR CONCRETE BLOCK WALL
WARNING:
Failure to provide adequate structural
strength for this component can result in serious personal
injury or damage to equipment! It is the installer's
responsibility to make sure the structure to which this
component is attached can support five times the
combined weight of all equipment. Reinforce the
structure as required before installing the component.
The wall to which the mount is being attached may have
a maximum drywall thickness of 5/8" (1.6cm).
WARNING:
ELECTRICAL SHOCK HAZARD!
CUTTING OR DRILLING INTO ELECTRICAL CORDS
OR CABLES CAN CAUSE DEATH OR SERIOUS
PERSONAL INJURY! ALWAYS make certain area behind
mounting surface is free of electrical wires and cables
before drilling or installing fasteners.
WARNING:
EXPLOSION AND FIRE HAZARD!
CUTTING OR DRILLING INTO GAS PLUMBING CAN
CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surface is
free of gas, water, waste, or any other plumbing before
cutting, drilling, or installing fasteners.
1.
Unfold wall plate (A) to prepare it for mounting to wall.
2.
Level wall plate (A) and mark locations of pilot holes at
desired mounting location.
NOTE:
For the iCXPFM3, use the inner four holes on wall
plate for installation.
3.
Drill 5/16" (8mm) diameter pilot holes into wall at
marked locations. Holes must be drilled at least 3 1/4
inches deep.
4.
Install four concrete anchors (Y) into drilled holes. Use
a hammer to tap anchors into holes.
IMPORTANT ! : The anchors must be installed
through any wall covering until flush with the concrete
wall.
5.
Using 1/2" (12.7mm) wrench, install screws (W) through
flat washers (X), wall plate (A) and into concrete
anchors (Y).
iC-PFM3 Series
13