Troubleshooting - Mi-T-M Corporation CHV Serie Manual Del Operador

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SYMPTOM
Pump motor will not start, or stops
Circuit breaker trips or fuse blows
the fuse box.
Motor runs but there is no discharge
at nozzle when trigger mechanism is
squeezed.
20

troublesHooting

PROBABLE CAUSE
Tripped circuit breaker or fuse
blown in circuit fuse box.
Loose or disconnected plug.
Tripped circuit breaker in unit.
Unit is frozen.
Circuit overload.
Inadequate water supply.
Kink in water inlet hose.
REMEDY
Disconnect all other plugs on the
circuit being used and reset
circuit breaker OR check and
replace fuse.
Reconnect plug.
Allow to cool and restart unit.
Allow to thaw. If any part of the
unit becomes frozen; excessive
pressure may build up in the unit
which could cause the unit to
burst resulting in possible serious
injury to the operator or
bystanders.
Check that the circuit is rated in
correctly. Disconnect all plugs
on the circuit. When connecting
to a circuit protected by fuses,
use time delay fuses only.
Ensure hose is 3/4" diameter and
incoming water supply is turned
on.
Remove kink.
Operator's Manual