Continued ... Function - part 1
Sensitivity to changes in
ON
speed.
Dip-switch 1÷4= On/Off/On/Off
1
Soft - start/stop.
ON
Dip-switch 1÷4= On/Off/Off/On
1
Operating time.
ON
Dip-switch 1÷4= Off/On/Off/Off
1
Operation time of "Pedestrian"
ON
function.
Dip-switch 1÷4= Off/Off/On/Off
1
Readjustment of the
stroke.
ON
Dip-switch 1÷4= On/On/On/On
1
Table 5
The intervention threshold for the rev. sensor is preset in case of motor speed reduction.
2
3
4
Acceleration time at the
start.
2
3
4
Braking time at triggering of the limit
2
3
4
2
3
4
The stroke adjustment is normally carried out when the control unit is switched on. Use this function if
the stroke is to be modified without switching the control unit off and on again.
(Dsw5÷8=
Not
used).
2
3
4
Continued ... Selectable values - part 2
Dsw5
Dsw6
% Change in the clos. phase
Off
Off
5% (Very sensitive)
On
Off
10% (def.)
Off
On
15%
On
On
20% (Little sensitive)
Dsw7
Dsw8
% Change in the open. phase
Off
Off
5% (Very sensitive)
On
Off
10% (def.)
Off
On
15%
On
On
20% (Little sensitive)
Dsw5
Dsw6
Acceleration time
Off
Off
0
On
Off
1
Off
On
2 (def.)
On
On
3
switches.
Dsw7
Dsw8
Braking time
Off
Off
0
On
Off
1
Off
On
2 (def.)
On
On
3
Dsw5
Dsw6
Dsw7
Dsw8
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
On
On
Off
Off
Off
Off
On
Off
On
Off
On
Off
Off
On
On
Off
On
On
On
Off
Off
Off
Off
On
On
Off
Off
On
Off
On
Off
On
On
On
Off
On
Off
Off
On
On
On
Off
On
On
Off
On
On
On
On
On
On
On
Dsw5
Dsw6
Dsw7
Dsw8
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
On
On
Off
Off
Off
Off
On
Off
On
Off
On
Off
Off
On
On
Off
On
On
On
Off
(sec.)
(sec.)
Seconds
5
10
15
20
30
40
50
60
80
100
120
140
160
180
200
220 (def.)
Seconds
5
10
15
20
25
30
35
40 (def.)
9