Remove the shower base from the carton. Do not destroy the shipping carton until after satisfactory inspection of the
1
product. Should initial inspection reveal any damage or defect in the shower finish, do not install the shower base. Jacuzzi ®
Luxury Bath's responsibility for shipping damage ceases upon delivery of the product in good order to the carrier. Refer any
claims of damage to the carrier. Any damage or defect claimed after installation is excluded from the warranty. Jacuzzi
is not responsible for any defect or damage that could have been discovered, repaired, or avoided by following this
inspection and testing procedure.
Plan the installation in relation to the finished wall surfaces. Take into account the dimensions of both the shower base and
2
the door enclosure. Install the optional trim parts after all other installation is completed.
Provide a minimum 5 x 5" opening in the subfloor. The opening should be located on the center lines (
3
hole, see Product Chart. The opening is to acommodate a 2" waste pipe. The waste pipe should be 1/4 to 1/2" above the
surface of the subfloor, see Figure 1. If the subfloor is level, no other preparation is necessary. Proceed to install the base.
If the subfloor is not level, level the shower base by spreading a floor-leveling compund, mortar, plaster, or minimal
expansion structural foam with a density of 5 pounds per cubic foot (lb/ft ³ ) minimum.
NOTE: The compound must make contact with the entire bottom surface of the base feet. The base is not to be supported
by the base flange. Both sides of a joint or splice of sub-floor should be level to each other.
Figure 1. Preliminary Rough-in (See Product Chart for drain location)
2 x 4" Blocking
*4½"
o
90
*4½" from subfloor to top of blocking
4
Position and install the base over the drain, see Figure 2. With the drain fitting passing over the center of the drain pipe,
lower the shower base carefully into place. Push down firmly until the base is in place. Check the level of the base in two
directions. A high shim is necessary at the back of the base for front-to-back leveling (see Figures 3 & 4). Advance to page 7
to continue this installation procedure.
Spread mortar or leveling compound evenly over
the entire area. Lift and lower the base over the
center of the drain pipe and set it into place.
Shower Base Installation And Operation
o
90
2"
5 x 5"
Waste
Opening
Pipe
(Max)
Center Drain
F igure 2
2 x 4" Blocking
o
90
*5½" from subfloor to top of blocking
Left Hand / Right Hand Drain
7/8" High Shim
*Height variation from 4 to 4-3/4"
(Left Hand And Right Hand Drain Models)
1/2" High Shim
*Height variation from 4-7/8 to 5-1/8"
www.jacuzzi.com
) of the base drain
Left Hand
Right Hand
*5½"
Models
Models
90
5 x 5" Opening (Max)
2" Waste Pipe
Figure 3 - Front to Back Leveling
(Center Drain Models)
Level
Figure 4 - Front to Back Leveling
Level
o
*4-3/16"
Front of base
*5-1/8"
Front of base