1.0 GENERAL COMMENTS
1.1 Warnings
This manual is designed to provide you with all the necessary information to allow correct
installation and maintenance of the instrument to provide optimum results and the maximum
operational lifetime.
For this reason it is important to read and follow the instructions contained in this manual as they
provide all the steps necessary to correctly install and maintain your equipment
Please keep this manual in a safe place for future consultation.
Before attempting to install the instrument please check the box contains everything listed
in the table of contents. This instrument should only be installed and operated by a
competent person.
Check that all electrical connections to be made are compatible with the data on the
pump's label.
Do not operate with bare hands and feet.
Install the instrument in a sheltered position away from external exposure.
In the case of malfunction, switch off the instrument and consult your dealer or Aqua's
technical department for advice on repair.
In order to ensure safe and correct operation only original Aqua spares should be used.
Aqua Spa. will not accept any responsibility for malfunction of the equipment due to tampering or
the use of non-original spares.
The unit should comply with electrical regulations in force in the country where it is installed.
The instrument may not be subjected to ambient temperatures over 45
1.2 Design standard
Our pumps are built according to the actual general directives endowed with CE mark in
conformity
with the following European directives:
N° 89/336/CEE regarding "electromagnetic compatibility"
N° 73/23/CEE regarding "low voltages", as also the subsequent modification N°93/68/CEE
N° 2002/95/CE, 2002/96/CE, 2003/108/CE " RoHs and WEEE directive
To give a long working life and for this instrument to continue to comply with the above, it is
necessary to ensure the procedures contained in this manual are rigorously applied.
Aqua Spa. will not accept any responsibility where this instrument is not installed or
2.0 TECHNICAL CHARACTERISTICS
2.1 General rules
Install the pump
on a vertical surface ( +/- 15
optional tank / shelf mount bracket should be used.
in a dry area and away from sources of heat. The ambient temperature must be between
o
o
0
C and 45
C.
in a well ventilated area with adequate access for maintenance.
at a suitable height above the chemical storage tank, but never more than 1.5 metres. If
the injection point is below the level of the chemical then use an injection valve or anti-
siphon valve.
Do not install the pump where it may be subject to the fumes from liquids unless
arrangements are made to install in a hermetically sealed enclosure..
2.2 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
2.3 Electric connection
Before installation ensure that the supply is adequately earthed and is fitted with a suitably
sensitive circuit breaker . Connect the pump to the power supply respecting the values
12/05/2010
maintained by skilled personnel.
o
). Where it is required to install on a horizontal surface the
Aqua Water Systems Ltd
Stourport-on-Severn - Worcestershire - DY13 9QB - UK
Telephone: 044 1299 827703 - Fax: 044 1299 827704
o
o
C. or less than 0
C
13