22. If the "combined nozzle" is used, set the switch in the brush to "HARD SURFACES" or else
"CARPET FLOORS". Start vacuuming (Fig.12).
WARNING: If you are using the brush attachment for the first time, remove the stops as
described on the label attached to the accessory itself.
WARNING: If while working you note that the vacuum accessory is sticking to much to
the surface on which it is being used, adjust the air flow inside the vacuum hose using the
lever on the grip and free the accessory.
At the end of the work, and before carrying out any type of maintenance, perform the following
operations:
1. Take the appliance to the designated place for emptying the collection tank.
2. Perform all procedures indicated in Chapter "MAINTENANCE".
3. Take the appliance to the designated storage area.
4. Insert the vacuum hose fastening clip in the support at the front of the handle in the collection
tank lid.
WARNING: Park the appliance in an enclosed place, on a flat surface; near the appliance
there must be no objects that could either damage it, or be damaged through contact with
it.
Proper maintenance of the collection tank guarantees better floor cleaning. Proceed as follows
to empty the collection tank:
1. Take the device to the dedicated maintenance area.
WARNING: The place this operation is carried out should comply with current
environmental protection regulations.
1. Make sure that the main switch is in the rest position, if not, disable it (Fig.11).
2. Check that the plug on the power cable has been taken out of the socket of the mains supply
(Fig.10), and if not, disconnect it.
WARNING: To prevent damaging the power cable, disconnect the plug from the mains
socket by directly pulling the plug and not the cable.
3. Release the vacuum cover retaining hinges on the side of the tank (Fig.13).
WARNING: Refer also to the symbols printed on the device itself.
4. Using the handle on the vacuum tank cover, remove the vacuum tank cover from the
collection tank. Put the vacuum tank lid gently on the floor.
5. Take out the air intake filter from inside the collection tank (Fig.14).
6. Take the paper filter bag out of the tank, taking care not to damage the cardboard support
inside the bag itself (Fig.15).
WARNING: operation valid only if the optional paper filter bag is used.
WARNING: If the optional paper filter bag is not used, empty the contents of the tank into
the container used for collecting dirt.
7. Clean the inside of the collection tank with a damp cloth.
8. Remove the vacuum motor filter latch from the vacuum head, rotate it according to the
direction indicated by the arrow (Fig.17).
WARNING: Refer also to the symbols printed on the device itself.
9. Remove the vacuum motor filter (Fig.18).
10. Clean the filters with a jet of air from a distance of at least 20 cm. Replace them if damaged.
WARNING: If persistent dirt remains on the filters, they can be cleaned under running
warm water. Wait until they are completely dry before putting them back in the device.
11. Using the handle on the vacuum tank lid, position the vacuum tank lid on the collection tank.
12. Secure the suction cover stop hinges, located at the side of the tank.
13. Disconnect the vacuum hose from the vacuum nozzle present in the collection tank (Fig. 16),
to release the vacuum hose from the nozzle rotate it according to the direction of the arrow.
WARNING: Refer also to the symbols printed on the device itself.
14. Disconnect the vacuum hose from the extension tube.
15. Clean the inside of the vacuum hose with a jet of air.
16. Disconnect the extension tube from the vacuum accessory.
17. Clean the inside of the extension tube with a jet of air.
18. Clean the vacuum accessory first with a jet of air, and then with a damp cloth.
19. Repeat the operations in reverse order to reassemble all the parts.
UM_Nano_verAB.indd 8
AT THE END OF THE WORK
MAINTENANCE
DISPOSAL
To dispose of the appliance, take it to a demolition centre
or an authorised collection centre.
Before scrapping the appliance, it is necessary to remove
and separate out the following materials, then send them
to the appropriate collection centres in accordance with
applicable environmental hygiene regulations:
Felt
Electric and electronic parts*
Plastic parts
Metallic parts
(*) In particular, contact your distributor when scrapping
electric and electronic parts.
TROUBLESHOOTING
This chapter lists the most common problems linked with the use of the appliance. If you are
unable to resolve the problems with the information given here, please contact your nearest
assistance centre.
PROBLEM
POSSIBLE CAUSE
The main switch is not
enabled.
The plug of the appliance's
power supply cable is not
correctly inserted in the
mains socket.
THE APPLIANCE
DOES NOT SWITCH
The electronic specifications
of the appliance do not
ON
correspond
electronic specifications of
the mains power supply.
The
power
damaged.
The
vacuum
incorrectly
the nozzle on the collection
tank.
The
vacuum
incorrectly connected to the
extension tube.
INSUFFICIENT
The
extension
VACUUM -
incorrectly
EXCESSIVE
the accessory that is being
PRODUCTION OF
used.
DUST
There
obstructing
circuit
extension
accessory).
The vacuum filter is blocked.
EC DECLARATION OF CONFORMITY
The undersigned manufacturer:
FIMAP S.p.A.
Via Invalidi del Lavoro, 1
37059 Santa Maria di Zevio (VR)
declares under its sole responsibility that the products
VACUUM CLEANERS mod. NANO 230V – NANO 115V
comply with the provisions of Directives:
2004/108/EC
EMC
2006/42/EC
MD
2011/65/UE
RoHS
2009/125/EC
Ecodesign
2013/666/EU
Ecodesign for vacuum
8
SOLUTION
Press the main switch.
Connect the plug of the
appliance's power supply
cable into the mains socket.
Check whether the technical
data on the serial number
with
the
plate
of
the
appliance
corresponds with the data
of the mains power supply.
Contact
a
qualified
cable
is
technician
as
soon
as
possible.
hose
is
Connect the vacuum hose
connected
to
correctly to the nozzle on
the collection tank.
hose
is
Connect the vacuum hose
correctly to the extension
tube .
tube
is
Connected the extension
connected
to
tube
correctly
to
the
accessory that is being
used.
is
something
the
suction
Remove the blockage in the
(vacuum
hose;
suction circuit.
tube;
vacuum
Remove the blockage in the
vacuum filters.
The person authorised to compile the technical file:
Mr. Giancarlo Ruffo
Via Invalidi del Lavoro, 1
37059 Santa Maria di Zevio (VR) - ITALY
Santa Maria di Zevio, 06/10/2014
FIMAP S.p.A.
Legal representative
Giancarlo Ruffo
6/16/2016 2:45:39 PM