3.2.9 Frequency
3.2.9.1 Frequency (V position):
range
Resolution Accuracy
66Hz
0.01Hz
660Hz
0.1Hz
6.6kHz
0.001kHz
10kHz
0.01kHz
-Range: 1 OHz-10kHz
-Input Voltage: ;.0. 2V AC (Input voltage should increase
along with the frequency)
3.2.9.2 Frequency (Hz position):
range
Resolution Accuracy
66Hz
0.01Hz
660Hz
0.1Hz
6.6kHz
0.001kHz
66kHz
0.01Hz
660kHz
0.1kHz
6.6MHz
1kHz
66MHz
10kHz
-Overload protection:250V DC /AC(rms)
-Input Voltage:3V peak to peak AC
3.2.9.3 Duty Cycle
range
Resolution Accuracy
1 -99%
0.1%
±(1.5% reading + 5 digits)
±(1.5% reading + 5 digits)
±(1.5% reading + 5 digits)
±2.0%
13
3.2.10 DC Current
range
Resolution Accuracy
660µA
0.1µA
6600µA
1µA
10µA
66mA
100µA
660mA
10A
10mA
Overload protection:
µA and mA position: Fuse FF600mA/1 OOOV ,
A position: Fuse FF1 OA/1 OOOV.
When the target current is larger than 5A, do not continue
measurement for more than 1 O sec. Pause for 1 minute
after the measuring.
3.2.11 AC Current
range
Resolution Accuracy
660µA
0.1µA
6600µA
1µA
10µA
66mA
100µA
660mA
10A
10mA
Overload protection:
µAand mAgrade: Fuse FF600mA/1000V ,
Aposition: Fuse FF10A/1000V.
-Frequency range: 40 - 400Hz
-Response: True RMS
When the target current is larger than 5A, do not continue
measurement for more than 1 O sec. Pause for 1 minute
after the measuring.
±(1.0% reading + 5 digits)
±(2.0% reading + 5 digits)
±(1.5% reading + 5 digits)
±(3.0% reading + 5 digits)
14