C-LOGIC 350 Manual De Instrucciones página 4

Idiomas disponibles

Idiomas disponibles

International Safety Symbols
Caution, risk of danger
Caution, risk of electric shock
Equipment protected throughout by double
insulation or reinforced insulation.
Suitable for live working
Both direct and alternating current
Conforms to UL STD. 61010-1, 61010-2-030
and 61010-031; Certified to CSA STD C22.2
NO. 61010-1, 61010-2-030 and 61010-031
Conforms to relevant European Union
directives
MEASUREMENT CATEGORY III is applicable
to test and measuring circuits connected to
CAT III
the distribution part of the building's
low-voltage MAINS installation.
OVERVOLTAGE CATEGORY lll is for
OVC III
equipment intended to form part of a building
wiringinstallation.
Representing the level of protection from
specified external conditions.
IP54
5: Dust-protected;
4: Protected against splashing water
12
AC/DC Voltage Measurements
Warnings
Observe all safety precautions when working on live
voltages.
1.T  ouch the test probes across the circuit being measured.
2.T  he tester will turn on automatically if the voltage
exceeds 12 volts.
3. The LEDs will indicate the voltage.
4. For AC voltage, the "+" and "-" LEDs will illuminate.
6. For DC voltage, the "+" LED will illuminate if the
instrument test probe is touching the positive side
of the circuit. The "-" LED will illuminate if the
instrument test probe is touching the negative
side of the circuit.
13
230V AC outlet
12V battery
12V battery
400
400
230
230
120
120
400
50
50
230
24
24
120
12
12
50
24
12
OVC I I I
OVC I I I
400V
400V
OVC I I I
50/60 Hz
50/60 Hz
400V
IP 54
IP 54
50/60 Hz
IP 54
CAT III
CAT III
400V
400V
CAT III
400V
14
Specifications
±12,24,50,120,230,400V
Voltage LED steps
Accuracy
-30% to 10% of indication
Response time
<0.1s
AC frequency range
50/60Hz
Operation time
30s maximum
10 minutes after maximum
Recovery time
operation time has been
reached
5℉ to 113℉(-15℃ to 45℃)
Operating Temperature
5℉ to 122℉(-15℃ to 50℃)
Storage temperature
80% maximum
Relative Humidity
Altitude
7000ft(2000m)
Safety
CAT III 400V,OVC III 400V
Weight
98.5g
Dimension
223x40x32 mm
MGL EUMAN, S.L.
Parque Empresarial de Argame,
C/Picu Castiellu, Parcelas i-1 a i-4
E-33163 Argame, Morcín
Asturias, España, (Spain)
loading