Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54

TEST MODE

This function is useful to check the correct communication via radio, and to perform
the wind and sun function test.
To activate the TEST function, hold the SET button down for around 2 seconds,
until the motor confirms the command by bringing the awning to half opening
distance. The test function lasts for 3 minutes, during which the wind and light level
settings can be checked, without waiting for the activation times. After 3 minutes,
the TM2 X SW sensor returns to normal mode function.
WIND FUNCTION TEST
To avoid errors during the wind function test, we advise setting the motor to manual
mode (wind only). With the anemometer blades moving, when the speed detected
by the sensor exceeds the set level, the motor will close completely the awning.
After the awning is closed and the anemometer blades stop turning, the awning
returns to halfway out if the automatic reopening function is active; if it is not, the
awning remains closed.
SUN FUNCTION TEST
Check that the motor is set to the automatic mode. When the sensor detects a chan-
ge in light intensity, it opens the awning if brighter than the set point or closes it if
weaker. This test can be repeated several times to establish the desired automatic
opening and closing level according to the light.
TM2 X SW
Set button
26
set
(2 sec)
A4518_6H80_Rev.A
Tabla de contenido
loading

Tabla de contenido