4. Open valves on unit to be evacuated. Open valves on recovery tank.
5. On Recovery System, rotate outlet valve to "OPEN" position. Rotate center valve to "RECOVER" position. Rotate inlet
valve to "OPEN" position.
6. Start Recovery System.
7. Check the sight glass for the presence of liquid flow. When liquid stops flowing, rotate inlet valve on Recovery System
to "CLOSED" position. When Recovery system is shut down due to vacuum, turn OFF the power switch. Reconnect
system for direct vapor recovery following instructions listed under "Operating Guide for Direct Vapor or Liquid
Recovery".
DO NOT fill tank more
than 80% of capacity!
WARNING: This product contains one or more chemicals known to the State of California to cause cancer,
4
FIGURE 2
Reco�ery
System
Appro�ed
Reco�ery
Tan�
RESET
OFF
5
34
Use Sight Glass
or
Manifold ��Sight Glass
birth defects or other reproductive harm.
www.mastercool.com
Air Conditioning
or
Refrigeration System
Vapor
Liquid