Connection To The Terminal - Mettler Toledo 64060625 Manual Del Usuario

Ocultar thumbs Ver también para 64060625:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

The cable length may be shortened if required before installation. To prevent damage, the cable
must not be connected to the battery while it is being shortened. To shorten, simply cut the cable to
the desired length, reconnect the green wire to the shield then protect this connection with heat
shrink or electrical tape. Finally, strip the blue and clear wires to the required length per the terminal
installation manual.
3.2.2.

Connection to the Terminal

The blue battery cable from the intrinsically safe power supply must be connected to the terminal
that it will power. Refer to the installation manual of the specific terminal for details on making this
wiring connection. The ground loop terminal of the cable must be attached to a grounding lug
inside the terminal and the blue and clear wires connect to the DC power input of the terminal. An
example termination to the IND226x is shown in Figure 3-3.
Figure 3-3: Wiring to the Terminal Connector
Table 3-1: Battery Cable Color Code
Wire Color
Signal
Blue
+12 VDC
Clear
Ground
Green
Shield
64062816
|
05
|
04/2016
METTLER TOLEDO NiMH Battery Pack Installation/Technical Manual
3-3
Tabla de contenido
loading

Este manual también es adecuado para:

64060627

Tabla de contenido