3.6 Configuration of the controller with the rotary switch
Fully programmable charge algorithm (see the software page on our
website) and eight preprogrammed charge algorithms, selectable with a
rotary switch:
Pos
Suggested battery type
0
Gel Victron long life (OPzV)
Gel exide A600 (OPzV)
Gel MK
Gel Victron deep discharge
Gel Exide A200
1
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (flooded)
Rolls Solar (flooded)
Default setting
Gel Victron deep discharge
2
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate (OPzS)
Rolls Marine (flooded)
Rolls Solar (flooded)
3
AGM spiral cell
Stationary tubular plate (OPzS)
Rolls AGM
4
PzS tubular plate traction batteries or
OPzS batteries
5
PzS tubular plate traction batteries or
OPzS batteries
6
PzS tubular plate traction batteries or
OPzS batteries
Lithium Iron Phosphate (LiFePo
7
batteries
Note 1: divide all values by two in case of a 12V system and multiply by two
in case of a 48V system.
Note 2: equalize normally off, see sect. 3.9 to activate
Note 3: any setting change performed with the pluggable LCD display or via
Bluetooth will override the rotary switch setting. Turning the rotary switch will
override prior settings made with the pluggable LCD display or via Bluetooth.
8
Absorption
V
28,2
28,6
28,8
29,4
29,8
30,2
30,6
)
4
28,4
Float
Equalize
V
V
@%I
nom
31,8
27,6
@8%
32,2
27,6
@8%
32,4
27,6
@8%
33,0
27,6
@8%
27,6
33,4
@25%
27,6
33,8
@25%
27,6
34,2
@25%
27,0
n.a.
dV/dT
mV/°C
-32
-32
-32
-32
-32
-32
-32
0