INSTALLATION
STEP
6
Install
the Premium
Control
Console
Locate door control within sight of door, at a minimum
height of 5 feet where small children cannot reach,
away from moving parts of door and door hardware.
If installing into drywall, drill 5/32" holes and use the
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 2).
1. Strip 1/4" of insulation from one end of bell wire and
connect to the two terminal screws on back of door
control by color: white to 2 and white/red to 1.
2. Pry off cover along one side with a screwdriver blade
(see Figure 1). Fasten with 6ABx1-1/4" self-tapping
screws (standard installation) or 6-32xl" machine
screws (into gang box) as follows:
• Install bottom screw, allowing 1//8" to protrude
above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid
cracking plastic housing. Do not overtighten.
• Insert top tabs and snap on cover.
3. (For standard
installation
only) Run bell wire up
walt and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Be careful
not to pierce wire with a staple, creating a short or
open circuit.
4. Connect the bell wire to the terminal screws on the
motor unit panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
DO NOT connect power and operate opener at
this time. The trolley will travel to the full open
position
but will not return to the close position
until the sensor beam is connected and properly
aligned.
To prevent possible SERIOUS INJURYor DEATH from
electrocution:
Be sure power is not connectedBEFORE installing door
control.
ConnectONLYto 24 VOLTlow voltage wires.
To prevent possible SERIOUS INJURYor DEATH from a
closing garagedoor:
Install door control within sight of garagedoor, out of
reachof childrenat a minimum heightof 5 feet, and away
from all moving parts of door.
NEVER permit children to operateor play with door control
push buttons or remotecontrol transmitters.
Activate door ONLYwhen it can be seen clearly,is properly
adjusted,and there are no obstructions to door travel.
ALWAYSkeepgaragedoor in sight until completelyclosed.
NEVER permit anyoneto cross path of closing garagedoor.
Outside
Keylock Accessory
Connections
To opener terminal screws: white to 2; white/red
to 1
HARDWARE
SHOWN ACTUAL
SIZE
Control Console (std installation)
_/
_1_
Insulated
Staples
Control Console (pre-wired)
Dry Wall Anchors
Figure 1
REMOVE
& REPLACE
COVER
TO Replace,
To Remove,
Insert Top
Twist
Tabs_ _First _ _
Here
Figure 2
PRE-WIRED
INSTALLATION
24 Volt
2-Conductor
Bell Wire in
Gang Box
2-Conductor
Bell Wire
Opener
m
Lighted
Push Button
,
L_:hct k
(BACK
VIEW)
PREMIUM
CONTROL
CONSOLE
18
Top
Mounting
Hole
Terminal
• Screws
Bottom
Mounting
Hole
Back Panel-
of Opener