Replacing the housing / electrical unit
If the housing or the electrical unit needs replacing, the earth must first be disconnected from the housing (see Chapter 'Installation of the earth
cable'). The electrical unit of the device is situated in the display box (W) on the device. The display box is glued and cannot be opened. If the
electrical unit is replaced, the entire box must be unscrewed and the earth wiring must be disconnected from the device. Unscrew the screw top
(U) and carefully disconnect the lamp holder from the lamp. Any loose parts, i.e. of the earth etc., must be carefully retained, as they are not
supplied with a new housing or electrical unit. In case of any doubt with regard to the connection, consult a recognised fitter.
Maintenance / dismantling
Always switch off the power supply during maintenance/dismantling of the device. The special lamp must be replaced after 4,500 operating
hours. Always keep the drawings at hand during maintenance/dismantling.
1 Unscrew the three-part couplings and drain the water from the device.
2 Open the pipe clips and carefully pull the device from the supports.
3 Unscrew the screw cap at the top of the device (U), remove the lid from the housing and disconnect the yellow lamp holder (V).
4 Then carefully pull the lamp (Q) from the quartz glass (X).
5 If the quartz glass (X) needs replacing, carefully remove it with a large, flat screwdriver (see drawing 6). Never use force!
7 When re-installing the lamp and/or the quartz glass, the housing must be in a vertical position in order to prevent damage to the lamp and the
quartz glass.
8 Unscrew the screw cap at the bottom of the device. Re-position the quartz glass onto the device. Ensure that the quartz glass is introduced
exactly into the glass holder (Y). Never use force! The quartz glass is very fragile.
9 The pump can be activated after all the parts have been returned to their original position. Please pay attention to the correct position of the
sealing rings when re-installing the parts. Check that there is flow and no leakage in the system.
10 Switch the Blue Lagoon Ozone UV-C on. Check whether the lamp (Q) is operating via the transparent outlet (R) of the unit.
Technical specifications
• TUV ozone lamp
• UV-C output (W)
• Swimming pool content (l)
• Max. throughput
• Max. pressure
• Max. ozone
• Connection size
• Length of the device
• Width of the device incl. reactor
Article number: B200005 Blue Lagoon Ozone UV-C 75,000 litres / 75 Watt (230V; 50/60Hz)
Article number: F980501 Ozone UV-C replacement lamp 75 watt
Terms of guarantee
The guarantee for this product covers manufacturing faults for a period of 24 months following the date of purchase. The lamp and the quartz
glass are not included in this guarantee. Claims under the guarantee can only be considered if the product is returned post-paid together with a
valid purchase receipt. Repairs under the guarantee may only be carried out by the supplier.
Guarantee claims that are caused by errors in the installation or in the operation of the device will not be considered. Defects originating from
poor maintenance are also excluded from the guarantee. The supplier will be held responsible in any way whatsoever for any damage caused by
the incorrect operation of the product. The supplier will not be liable for any consequential damage caused by the breakdown of the device.
Complaints regarding transportation damage will only be considered if the damage was established or confirmed on delivery by the carrier or the
postal authorities. A claim can only be made against the carrier or the postal authorities if this has been done.
0904_118_Manual_BL_Ozone.indd 7
36 T5 HO VH 75 W 4P-SE-BY1
25 Watt
75,000 l
25,000 l/h
3 bar
0.6 gram
Ø 63mm
100 cm
75 cm
7