GYS GYSFLASH 30.12 PL Manual Del Usuario página 11

Ocultar thumbs Ver también para GYSFLASH 30.12 PL:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
lithium battery manufacturers indicate the battery lead equivalent (EqPb) which corresponds to the capacity of a lead-acid battery
with the same starting performance. For instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid
battery of about 30 Ah.
SHOWROOM/DIAG mode (13.7 V / 30 A max.) :
Mode designed to compensate up to 30 A the current consumed on the battery of a vehicle in demons-
tration by delivering a stabilised voltage of 13.7 V. This mode is suited for lead-acid and lithium batteries.
When the indicator
the current absorbed by the battery is higher than the charger maximum current (30 A) and that the
battery might end up being discharged.
The current supplied by the charger is indicated using the LED indicators
• Lead-acid charging curve :
The GYSflash 30.12 PL features a 7 step charging curve designed to ensure optimal charging of lead-acid batteries.
1
U
I
Analysis
<1s
CHARGE
OK
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion,
wrong battery...)
2
Step
: Recovery (
- 10 A)
Recovering damaged elements due to a prolonged deep
discharge.
3
Step
: Test
Sulfated battery test
4
Step
: Desulfation (15.8 V)
Battery desulfation algorithm.
GYSFLASH 30.12 PL
Option Supply (13.7 V / 30 A max.) :
Feature designed to turn the charger into a stabilised power source with a regulated voltage
of 13.7 V and a supply of current up to 30 A. This mode can be used without a battery.
To select this option, place the charger in Showroom mode and press the
until the
indicator flashes.
is on, the voltage is correctly regulated. If indicator
I
0 A
1 A
6.3 A
2
3
Recovery
Test
Desulfation
Max 8h
<1s
- 3 A /
- 5 A /
7.7 A
13.5 A
16.5 A
4
5
Charge
Max 12h
Max 20h
5
Step
: Charge (
Maximum current fast charge to reach 80% charge level.
6
Step
: Absorption (14.6 V)
Constant voltage charge to reach 100% charge level.
7
Step
: Floating charge (13.6 V)
Maintains battery charge level at its maximum.
flashed, this means that
6
7
Floating
Absorption
charge
Max 8h
No limit
- 7 A /
- 15 A /
EN
button
:
27 A
30 A
- 30 A)
11
Tabla de contenido
loading

Tabla de contenido