4. SAFETY MEASURES
4.1 Technician
The technician performing the installation and adjustment of the valve should be properly
trained, and has to be fully aware of the dangers involved while working on hydraulic
equipment under pressure.
Furthermore he must wear all individual protection items required.
4.2 Operations
• The interventions allowed are only those described in this manual.
• In case of damage or break down request replacement from GMV.
Never open the valve!!!
4.3 Warning for connection tubing
• The connection tube is a fundamental component of the rupture valves system. It can be
produced with copper tube Ø 6x1 (max length 10 m) or with flexible tube 3/16" (on request).
• In case of wearing or loss, require original spare parts only.
• With a copper tube, the bents must have a minimum curving ray of 30 mm.
• Using a flexible tube, it is advisable to use the minimum curving ray declared by the
manufacturer.
• Please always foresee space enough to inspection the tube all along its length and to
replace it if necessary.
5. PACKING
The valve is packed in a card box containing:
1) n° 1 VC 3006 valve with (1",1"¼,1"½) terminal connector of with (2"and 2"½ ) plastic cap
2) n° 4 Screws
3) n° 4 "Schnorr" washer
4) n° 1 O-Ring
5) n° 1 Installation manual
The box is labelled with the type of valve, purchase order number, and valve serial number.
4
17
1
2
3
GB