Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases.
Do not vent gases into the atmosphere.
Refrigerant type: R32
GWP
(1)
value:
675
(1)
GWP = Global Warming Potential
1
Please fill in with indelible ink,
¢
1 the factory refrigerant charge of the product,
2 the additional refrigerant amount charged in the field and
¢
1 + 2 the total refrigerant charge
¢
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the service cover).
Contains fluorinated greenhouse gases
R32
=
1
GWP: 675
2
=
2
1
1
+
2
=
GWP × kg
=
1000
a
Factory refrigerant charge: see unit name plate
b
Additional refrigerant amount charged
c
Total refrigerant charge
d
Greenhouse gas emissions of the total refrigerant charge expressed as tonnes CO
e
GWP = Global warming potential
NOTICE
In Europe, the greenhouse gas emissions of the total refrigerant charge in the system (expressed as tonnes
CO
-equivalent) is used to determine the maintenance intervals. Follow the applicable legislation.
2
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in kg] / 1000
2
Fix the label on the inside of the outdoor unit. There is a dedicated place for it on the wiring diagram label.

IMPORTANT

kg
kg
kg
tCO
eq
2
1-5
-equivalent
2

Hide quick links:

Tabla de contenido
loading

Tabla de contenido