STEP 4:
Replace primary sump pump and Battery Backup
Pump assembly into the sump basin. The top of
the Battery Backup Pump should be at least 4"
below the top of the sump and at least 1" above
the highest water level of the primary sump pump.
Connect the remaining
discharge pipes,
check valve and
couplings.
Insert
Check
Valve
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
INSTALLATION
STEP 5:
Attach the automatic float switch to the discharge
pipe so that the switch is tethered 1-1/4" from the
discharge pipe. Use the supplied wire straps to
mount the float switch cord to the discharge pipe.
STEP 6:
Feed the pump and float switch cords through
the sump pump vent or utility hole and cover the
sump with the
sump cover.
5
Discharge Pipe
Float Sensor
Backup Pump
Suction Inlet
Check Valve
Float
Switch
Cord
Power Cord