SR2-SR3
English
Safety
In addition to the devices provided by the local regulations in force,
install:
devices
to be
provided by
Electrical emergency or
the customer
cut-off switch
Fire fighting extinguisher
compliant with the
regulations in force
Leak detection system
for the refrigerant gas
Safety labels
Installation
Step
procedure
1
2
3
4
5
6
13. Wiring
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Provide a suitable grounding system!
i
The systems must be set up in accordance to the norms that regulate manufacture,
installation, use, and maintenance foreseen by the norms in force in the country where
the refrigeration system is installed.
To ensure normal operation, the maximum variation of the voltage must range between
+/- 10% of the nominal value.
Responsability
Customer
Installer
ARNEG
34
Device
Carefully examine the installation area. Eliminate any danger to the
operator.
Place the refrigeration system in the final installation location.
to avoid structural stress, remove the packaging only if the
refrigeration system is placed in the inal location
Remove the brackets and the temporary feet used for transport.
Place the refrigeration system gently.
Check:
- the horizontal levelling with a spirit level (Fig. 6)
- that all support feet are on the floor.
Fix the vibration dampers to the floor.
Correct any levelling error with suitable shims.
Place the refrigeration system so as to AVOID stretching the power
and connection cables
prepare the power supply line up to the refrigeration
system connection point.
supply anchoring devices for all In/Out cables of customer's
premises.
ARNEG S.p.A. denies all liability with respect to the user or
third parties for:
- damages due to failure or malfunction of systems
installed upstream of the refrigeration system.
- damages to the refrigeration system due to malfunctions
of the electrical system
Position
outside the area
next to the entrance
next to the emergency
switch
in the area
on the access door
Action
Features
cuts off power to the
entire area
suitable for live parts
present within the area
triggers a visual and
acoustic alarm
indicate the type and the
total amount of gas
05060162 00 02/02/2016