1 Product description

The COMPACT CLASSIC cooling unit has been designed for installation in sailing or
motor boats, to meet the specific requirements of the marine environment in terms
of performance and reliability. All necessary components are supplied for COMPACT
CLASS installation: the cooling unit lets you turn any properly insulated compartment
on the boat into a functional, high-energy performance refrigerator. In some cases it
can even be configured as a freezer.
The COMPACT CLASS system is divided into two main sections to simplify installation:
the condenser unit (compressor unit) and the evaporator connected by means of a
quick coupling hose.
Refrigerant runs through the circuit, passing through the external condenser
unit (compressor unit) and the evaporator located inside the compartment to be
cooled (useful part of the cycle). When installing the unit, it is important that the
compartment that will house the compressor be well ventilated, allowing air to
circulate as it enters from the lower part and exits from the upper part, permitting
aeration and therefore correct machine cooling, preventing dangerous overheating.
The unit is provided pre-filled with refrigerant and is ready for use upon supply. The
compressor is supplied watertight and leak-proof.
Once assembled, the COMPACT CLASS system offers low power consumption with
minimal noise. Marine refrigerators made with COMPACT CLASS are capable of
functioning at angles of up to 30°. Greater angles can cause permanent damage to
the compressor.
To reduce electrical consumption and maintain internal compartment temperature,
it is important that the compartment to be used as a refrigerator be suitably
insulted with polyurethane foam or similar material, with a thickness contained in
the following tables related to the possible operation configurations (compartment
volumes and operating environment temperature). The configurations indicated in
the table consider the following conditions for outdoor temperature and insulation:
Operating temperature conditions:
SN= operation at environment temperature from 10°C to 32°C
ST= operation at environment temperature from 16°C to 38°C
T= operation at environment temperature from 16°C to 43°C