h) Chimney covers must not affect
chimney draw.
Incorrect
i) Clean the chimney at least once a year.
j) The joints of the pipes that form the
chimney, in the case of metal pipes, must be sealed
with refractory putty.
k) External metal chimneys must be built
with special double insulated pipes for solid fuels.
4. OPERATING INSTRUCTIONS
Once installed in its final destination, check the seal
of all of the joints, to prevent the entry of air from
outside that is detrimental to the draught.
Before covering the stove with brick or any other
type of fire-resistant material, it is important to
check that it is operating properly.
Lighting the stove for the first time.
The first time that the stove is lit should be carried
out at a low heat for three or four hours to stabilise
Same as diameter
al least
Correct
Fig.9
Fig.-10
the various parts and thus avoid any possible
breakage.
The first time that the stove is lit it is advisable to
have the windows open to evacuate any
fumes/smoke and smells that may be produced by
the combustion of solvents from the protective
paint or any other material.
Primary air. Control.
Air for combustion is provided by means of the
primary air valve. (Fig.11 and 12)
OPEN
Fig. 12
33
CLOSE
Fig. 11