Description of the connections (Fig. 4)
1 - Power of photocells or external receivers
2 - Contact the photocells
3 - Earth GND (negative supply, common photocells and START)
4 - START button (Wall or key selector)
To safeguard the Automation and avoid damaging components during connection, disconnect it from the electrical current during
assembly. Remember that there are clear and strict rules that must be followed, both having to do with installation of electrical
systems, such as those having to do with automatic doors. The installer will be responsible for any damage caused.
Note: Contact the Technical Department to obtain the wiring diagram in case of doubt.
Programming the controller board
Keep trolley locked,Pull and push the door by hand,make sure the trolley connects with the shuttle.
Turn on the power, the courtesy light is on for several seconds, at the same time, the LED displays the number
99 to 11.
When the operator turns to standby, it displays (--).
Press and hold SET until it displays P1.
Press SET to enter open programming mode. It displays OP.
Press UP and hold, when the door reached the the open position,
Press SET to confirm the open position. It displays CL,
Press and hold DOWN, when the door reached the close position. Release DOWN (it flashes CL). Press SET
to confirm.
The door opens and closes automatically to map the open and close sensitivity force requirements.
Setting is complete, it displays (--).
Press CODE, it displays "Su". Press 2 times the botton on the transmitter. "Su" flashes.
The transmitter programming is complete and return to standby mode, it displays (--).
To clean all the transmitters, press and hold CODE more than 8 seconds, it flashes "dL". All the codes were
cancelled.
Can programm 20 codes. When the memory is full, it blinks "Fu".
Startup
Setting Open and Close Positions
release UP (it flashes OP).
it's time to program the closing position
Transmitter Programming
99
11
--
P1
OP
OP
CL
.
CL
OP
CL
--
SU
--
DL
FU