T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L CONTENTS Tecal 140S Calibrator Operator’s Manual page SAFETY AND INSTALLATION English Français Deutsch Español THE CALIBRATOR...
Página 4
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L PAGE 2...
Página 5
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L NOTES PAGE 3...
Servicing under this material. guarantee should be obtained from the supplier. Techne have taken great care in the design of these units Notwithstanding the description and specification(s) of the to protect operators from hazards, but users should pay units contained in the Operator’s Manual, Techne hereby...
Garantie combustibles risquent de prendre feu. Techne a apporté un soin tout particulier à la conception de L’appareil est garanti contre tout défaut ou vice de fabrication ces appareils de façon à assurer une protection maximale pour la durée figurant sur la carte de garantie, à...
Geräteteilen durchzuführen. Sicherheit des Anwenders Diese Gebrauchsanleitung wurde ausschließlich dazu Alle Benutzer von Techne Geräten müssen Zugang zu der erstellt, um Kunden die Handhabung der Techne-Geräte entsprechenden Literatur haben, um ihre Sicherheit zu zu erleichtern. Nichts in dieser Gebrauchsanleitung darf gewähren.
Cuando haya finalizado el calentamiento de muestras, materiales combustibles. recuerde que las piezas del equipo, tales como tubos, Techne ha puesto gran cuidado en el diseño de estos bloques y demás accesorios, pueden estar muy calientes. aparatos para proteger al usuario de cualquier peligro; aún Tome las precauciones mencionadas anteriormente.
HIGH TEMPERATURES ARE DANGEROUS: they can cause serious burns to operators and ignite combustible material. Techne have taken great care in the design of these units to protect operators from hazards, but operators should pay attention to the following points: •...
The unit must be transported in the original packing to avoid damage. The packing comprises; the unit in the soft carrying case packed with foam into an outer cardboard box. Techne accepts no responsibility for damage incurred unless the unit is correctly packed and transported in this way.
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L WHEN YOU SWITCH ON When you first switch on, the display will show the edition of the software which your unit uses.
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L The DOWN ARROW Button ∇ ∇ ∇ ∇ ∇ When the SET temperature button is held down and the DOWN ARROW button is pressed, the set temperature is decreased.
The cooling fan in the calibrator will automatically switch off if there is a chilled water supply. A Techne CH-5 chiller may be used to supply chilled water but in an ambient above 20°C it may not achieve the lowest temperatures. Switch on the chiller unit before the calibrator and allow the chiller to stabilise for 15 minutes before performing a calibration.
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L RS232 SERIAL INTERFACE The calibrator may send data logging information to an IBM PC or compatible computer by connecting the unit and the PC via an RS232 cable, and installing the "Calsoft"...
Please include any details of the fault observed and remember to return the unit in its original packing. The insert must be removed from the unit and packed separately within the case. Techne accept no responsibility for damage to units which are not properly packed for shipping: if in doubt, contact your supplier.
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L Replacement parts Each unit is supplied with an extraction tool, a soft carrying case and a mains cable.
T E C A L 1 4 0 S O P E R A T O R ’ S M A N U A L Inserts Inserts are made from aluminium or aluminium-bronze and must be ordered separately from the calibrator. Each insert is stamped for identification. A blank insert is available which may be drilled to suit your application.