CM2C40
Voltage Sense External Power Source
Unit extends and stays extended when voltage from an external source is applied across pins 3 and 4 on connector J1. When
voltage is removed unit retracts. (See figure 30) and (See figure 33)
Voltage Sense Internal 24V DC Power Source
The 24V DC power supply that is built into the unit can be used to power external devices by using pins 5 and 6 on connector J1.
NOTE:
Using this input will force a complete UP/DOWN cycle of the unit. No other inputs, with the exception of error inputs, are
available until the cycle has completed. (See figure 30) and (See figure 34)
Extend Error Input
NOTE:
Units are shipped with error contacts "Normally Open". To set unit to respond to "Normally Closed" error contacts contact
a Chief Technical Support representative.
When unit receives an Extend error signal during an extend operation, the unit will immediately stop and reverse direction.
(See figure 30) and (See figure 35)
Retract Error Input
NOTE:
Units are shipped with error contacts "Normally Open". To set unit to respond to "Normally Closed" error contacts contact
a Chief Technical Support representative by calling 1-800-582-6480, or by visiting www.chiefmfg.com.
When unit receives a Retract error signal during a Retract operation, the unit will immediately stop and reverse direction.
(See figure 30) and (See figure 36)
22
Figure 33
Figure 34
J2
Figure 35
J2
Figure 36