Technical specifications

Model
Sizes
Capacities
Cooling
Heating
Power Supply
Consumption
Cooling / Heating
Nominal flow
Available pressure
Noise level (1 m.)
Dimensions (Height / Width / Depth)
Nett Weight
Tubing
Gas diameter
Liquid diameter
Maximum tubing length
Maximum elevation tubing
Nominal cooling capacity is based on: Indoor air temp. = 27°C DB/19°C WB. Outdoor air temp. = 35°C DB, 5-meter tubing.
Nominal heating capacity is based on : Indoor air temp. = 21°C DB - Outdoor air temp. = 7°C DB/6°C WB, 5-meter tubing.
ATTENTION
Your product is marked with this symbol. This means that at the end of its service life it should not be mixed
with other non-classified household waste. Therefore, disposal should be carried out in compliance with the
corresponding local and national regulations, in a correct and environment-friendly manner.
The dismantling of the air conditioning unit, as well as the processing of refrigerant, oil and other components,
should be carried out by a qualified technician and in compliance with the applicable legislation.
Contact your local authorities for further information
All data and dimensions are subject to change without prior notice.
12
12
kW
3.5
kW
3.6
V.ph.Hz
230.1.50
kW
1.2 / 1.1
2.1 / 1.8
m
/h
600
3
Pa
25
dB (A)
36 / 38 / 40
38 / 40 / 42
mm
220 / 913 / 680 266 / 1 012 / 736 268 / 1 270 / 504 290 / 1 251 / 744 290 / 1 251 / 744 330 / 1 251 / 788
kg
27
1/2"
1/4"
m
20
m
15
GB
EUKC
18
24
5.0
7.0
5.7
8.0
2.7 / 2.5
840
1 400
40
80
40 / 42 / 44
46 / 48 / 50
36
37
1/2"
5/8"
1/4"
3/8"
20
30
15
15
36
42
10.0
12.0
11.0
14.0
230.1.50
380.3.50
380.3.50
4.0 / 3.5
5.3 / 4.9
2 000
2 000
150
150
46 / 48 / 50
57
57
3/4"
3/4"
1/2"
1/2"
50
50
30
30
60
16.0
18.5
6.5 / 5.5
2 500
150
48 / 50 / 53
66
7/8"
1/2"
50
30