ENGLISH
INSTALLATION
In order to attach this device to the wall, use the
two holes on top and the four holes located inside
the equipment.
In the COIN TIMER models
supplied with BOX (tray containing the balls for
billiard), you can also use the 2 internal holes of
the BOX itself. To avoid that the users can
disconnect the electricity plug, the COIN TIMER
has been constructed to be connected directly to
the supply. Therefore the cable you are equipped
with is to be considered useful only for an initial
test before the definitive installation.
The connections must be carried out by qualified
personnel following the scheme of Fig.1.
WARNING : This equipment must be grounded.
The 230-Vac electrical feed must be protected
with an automatic switch at its source.
Fig. 1 - Connections.
ALARM load POWER:
5A Max, 250Vac Max.
SERVICE load POWER:
5A Max, 250Vac Max.
PROGRAMMING
Fig. 2 - Push buttons.
T O TA L
F R E E
P L AY
F1
PROG.
+
-
To go to the first step of the programming press the
C O I N T I M E R
TECHNICAL INSTRUCTIONS
COIN TIMER
internal card
{
ALARM
{
SERVICE
Visualizer
card
LITHIUM BATTERY
See chapter on TECHNICAL DATA on page 8.
Connect the electrical feed of the COIN TIMER to
the terminals
Connect the earth cable to the terminal .
Between the terminals
SERVICE
is available, it is operated with the
insertion of money. As for the COIN TIMER for
billiard, the
eventual electronic scoreboard.
Between the terminals
available, through it an eventual alarm light is
connected. It will turn on at the last minute of the
game. In case there is the BOX, once the time is
over it will flash until the balls are replaced into the
BOX itself.
2 FUSES:
6.3A F, 250 Vac
8
7
6
5
load
load
PROG.
button (see Fig.2). By pressing again
PROG.
you can then proceed to the successive
steps, or to go back press the
After the last step the programming ends. The
flashing
character on the left of the display
indicates which step is active while the number that
a p p e a r s o n t h e r i g h t c a n b e m o d i f i e d .
First step:
U 0.05
U
0.05
This depends on the value of the coins circulating
10
1-4
: 230Vac, 50-60Hz, 250mA Max.
5-6
the time contact
SERVICE
load is the light and/or the
7-8
the contact
8
7
4
3
2
1
~
~
COIN TIMER Power Supply:
230V, 250mA Max.
FREE-PLAY
MONETARY UNIT
3
ALARM
is
6
5
CONNECT
TO METAL
button.