En el
EJEMPLO DE CÓDIGO 5-3
EJEMPLO DE CÓDIGO 5-3
# lom -e 11
LOMlite Event Log:
Fri Jul 19 15:16:00 commando-sc lom: Boot: ScApp 5.13.0007, RTOS
23
Fri Jul 19 15:16:06 commando-sc lom: Caching ID information
Fri Jul 19 15:16:08 commando-sc lom: Clock Source: 75MHz
Fri Jul 19 15:16:10 commando-sc lom: /N0/PS0: Status is OK
Fri Jul 19 15:16:11 commando-sc lom: /N0/PS1: Status is OK
Fri Jul 19 15:16:11 commando-sc lom: Chassis is in single
partition mode.
Fri Jul 19 15:27:29 commando-sc lom: Locator OFF
Fri Jul 19 15:27:46 commando-sc lom: Alarm 1 ON
Fri Jul 19 15:27:52 commando-sc lom: Alarm 2 ON
Fri Jul 19 15:28:03 commando-sc lom: Alarm 1 OFF
Fri Jul 19 15:28:08 commando-sc lom: Alarm 2 OFF
Comprobación de los ventiladores (lom -f)
Para comprobar el estado de los ventiladores, escriba:
EJEMPLO DE CÓDIGO 5-4
# lom -f
Fans:
1 OK speed self-regulating
2 OK speed self-regulating
3 OK speed self-regulating
4 OK speed self-regulating
5 OK speed self-regulating
6 OK speed self-regulating
7 OK speed self-regulating
8 OK speed self-regulating
9 OK speed 100 %
10 OK speed 100 %
#
Si es necesario reemplazar un ventilador, póngase en contacto con el representante
de ventas local de Sun y comuníquele el número de pieza del componente que
necesita. Si desea obtener más información, consulte la publicación Sun Fire
V1280/Netra 1280 Service Manual.
Capítulo 5 Utilización de LOM (Lights Out Management) y el controlador del sistema desde Solaris
se muestra un registro de eventos de ejemplo.
Ejemplo de registro de eventos de LOM (el evento más antiguo
aparece primero)
Ejemplo de resultados obtenidos con el comando lom -f
49