Technical data
General data and operating conditions
Protection of persons and equipment
Short−circuit strength
Earth−fault strength
Protective measures
against
Cyclic mains switching
Starting current
68
EN 61800−5−1
Connection:
Motor
Motor holding brake,
brake resistor
PTC, control terminals
EN 61800−5−1
Connection:
Motor (at controller
enable)
Motor (during
operation)
Brake resistor, PTC
Short circuit on the motor side at switch−on and
l
during operation
Motor stalling
l
Motor overtemperature
l
– Input for PTC or thermal contact
– I
l
Switchings/minute
l
Switchings/hour
Switching pause
l
£ 2 x I
N
l
To a limited extent, the
controller is inhibited, error
acknowledgement required
No
Full
To a limited extent, the
controller is inhibited, error
acknowledgement required
No
No
2
t monitoring
3
Max. 20
After switching the mains 3
times in one minute, there
must be a switching pause
of 9 minutes.
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 8.3