Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

USE AND CARE GUIDE
DIGITAL MULTIMETER
Questions, problems, missing parts? Before returning to the store,
call Home Depot Customer Service
1-877-527-0313
HOMEDEPOT. COM
We appreciate the trust and confidence you have placed in Commercial Electric through
the purchase of this digital multimeter. We strive to continually create quality products
designed to enhance your home. Visit us online to see our full line of products available
for your home improvement needs. Thank you for choosing Commercial Electric!
Item # 119 701
Model # MAS830B
THANK YOU
Table of Contents
Table of Contents ...
.........................
Safety Information
.........................
Warranty .........................................3
Pre-Operation ................................. 4
Safety Information
Please read this manual carefully and pay attention to related safe working standards
before using this meter. Protection provided by the instrument will be impaired if
used in a manner not specified by the manufacturer.
Symbol
Definition
Indicates important safety information, refer to the operating manual.
Dangerous voltage may be present.
Double Insulation, Protection Class ll.
This product conforms to UL STD. 61010-1, pollution 2.
Measurement category II, which is for measurements
performed on circuits directly connected to the
CAT II
low voltage installation.
The fuse must be replaced with the rating specified
in this manual.
Earth (ground).
2
Operation
.......................................
2
Maintenance .................................. 9
Care and Cleaning ....................... 10
2
7
Tabla de contenido
loading

Resumen de contenidos para Commercial Electric MAS830B

  • Página 1 HOMEDEPOT. COM THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this digital multimeter. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available...
  • Página 2: Pre-Operation

    Safety Information (Continued) Pre-Operation PRECAUTIONS PACKAGE CONTENTS WARNING: This manual contains WARNING: When the meter is linked information and warnings necessary to a circuit to be measured, do not for safe operation and maintenanceof touch unused terminals. the meter. It is recommended that you read and understand this instruction WARNING: Never use the meter to manual thoroughly prior to using the...
  • Página 3 Pre-Operation (Continued) Pre-Operation (Continued) PRODUCT SPECIFICATIONS AC VOLTAGE SPECIFICATIONS Component Specification Measuring Range Resolution Accuracy Maximum voltage ±1.2% rdg ± 10dgt 200V 100mV between terminals and CAT II 600V ±1.2% rdg ± 10dgt 600V earth (ground) Additional specifications: Fuse protection F1 250mA/250V F2 10A/250V Battery 9V battery, NEDA 1604 or 6F22...
  • Página 4 Operation Operation (Continued) Completing an AC Voltage Measurement Completing a DC Voltage Measurement Connect the red test lead (G) to the Connect the red test lead (G) to the V Ω m A jack (F) and the black test lead Ω...
  • Página 5: Care And Cleaning

    Maintenance (Continued) Operation (Continued) If the battery icon appears on the LCD display, it indicates that the battery needs to be Performing a Diode Test replaced. The fuse rarely requires replacement. A blown fuse is usually the result of operator's error. Connect the red test lead (G) to the V Ω...
  • Página 6 Questions, problems, missing parts? Before returning to the store, call Home Depot Customer Service 1-877-527-0313 HOMEDEPOT. COM Retain this manual for future use.
  • Página 7: Tabla De Contenido

    1-877-527-0313 HOMEDEPOT. COM GRACIAS Nosotros le agradecemos la confianza y seguridad depositada en Commercial Electric a través de la compra de este multímetro digital. Nos esforzamos por crear continuamente productos de calidad diseñados para realzar su hogar. Visítenos en línea para ver nuestra línea completa de productos disponibles para sus necesidades de...
  • Página 8: Garantía

    Información de Seguridad (Continuación) Pre-Funcionamiento CONTENIDO DEL EMPAQUE PRECAUCIONES ADVERTENCIA: Cuando el medidor esté ADVERTENCIA: Este manual contiene información y advertencias necesarias conectado a un circuito de medición, para la operación segura y el nunca toque los terminales no utilizados. mantenimiento del medidor.
  • Página 9 Pre-Funcionamiento (Continuación) Pre-Funcionamiento (Continuación) ESPECIFICACIONES DEL PRODUCTO ESPECIFICACIONES DE VOLTAJE CA Componente Especificación Rango de Medición Resolución Precisión ±1.2% rdg ± 10dgt Voltaje máximo entre los 200V 100mV CAT II 600V ±1.2% rdg ± 10dgt terminales y tierra (puesta 600V a tierra) Especificaciones Adicionales: Fusible de protección...
  • Página 10: Realizando Una Medicion De Voltaje De Cc

    Funcionamiento (Continuación) Funcionamiento REALIZANDO UNA MEDICION DE REALIZANDO UNA MEDICION DE VOLTAJE CA VOLTAJE DE CC Conecte la punta de prueba roja (G) al Conecte la punta de prueba roja (G) conector VΩmA (F) y la punta de prueba al conector VΩmA (F) y la punta de negra (H) al conector COM (E).
  • Página 11: Mantenimiento

    Funcionamiento (Continuación) Mantenimiento(Continuación) Si el icono de batería aparece en la pantalla LCD, esto indica que la batería necesita Compléter un teste de diode ser reemplazada. Conecte la punta de prueba roja (G) El fusible rara vez requiere ser reemplazado. Un fusible quemado suele ser el al conector VΩmA (F) y la punta de resultado de un error del operador.
  • Página 12 ¿Preguntas, problemas, piezas faltantes? Antes de regresarlo a la tienda, llame a Servicio al Cliente de Home Depot 1-877-527-0313 HOMEDEPOT. COM Conserve este manual para referencia futura.

Tabla de contenido