3
Technical Data
152mm X 165mm X
Size
178mm
(6" X 6.5" X 7.0")
Weight
1.2 kg (2.6lbs)
Minimum
Dispense
0.020 Seconds
Time
Input Voltage
24VDC
Rated Power
10W
Air Input
100 psi (6.9 bars) Max.
Pollution
II
Degree
Installation
I
Category
Altitude up to 2,000m
Indoor Use
(6,562ft)
Operating
0˚C to 50˚C (32˚F to
Temperature
122˚F)
4
Installation
Use 5 micron Filter –Regulator –Loctite 985397 or
equivalent for inlet air supply
1
2
5
4.1 10ml or 30ml syringe adapter attaches to Pulsed Air
Outlet (7) and syringe barrel.
Max.
Relative
Humidity
Air Output
Maximum
Dispense
Time
Vacuum
Timer
Cycle Mode
Timing
Repeat
Tolerance
Cycle Rate
LCD
Storage
Temperature
3
4
Fig. 4.1
6
80% for temperature up to
31˚C (87.8˚F) Decreasing
linearly to 50% relative
humility at 40˚C (104˚F)
0-100 psi (0-6.9 bars)
99.999 seconds
406mm (16") of Hg
0.020 - 99.999 seconds
Timed, Incremental, Manual
+/- 0.001%
600 cycles/min
16 X 2 display segments
-10˚C to 60˚C (14˚F to
140˚F)
Items
Description
1
To Air Source
Air Filter –sold
2
separately
3
Power Adapter
Foot Switch
4
5
Syringe Adapter