3 -OPERATION
The Nature Compact appliance has been
equipped with an electronically controlled forced
convection fan and combustion air intake valve.
In order to adjust the settings, point the remote
control towards the appliance.
The infra-red receiver is located at the bottom
left of your appliance.
FAN The fan can be adjusted in two ways:
-Automatic: This mode has precedence over the
manual mode.
In this mode, the fan will operate at speed 1 (1/3
of the fan's full speed) when the temperature
probe reaches 40ºC.
Two safety measures are enables in this mode.
When the probe reaches a temperature of 70ºC,
the fan will operate at speed 2 (2/3 of the fan's
full speed).
When the probe detects a temperature of 90ºC,
the fan will operate at full speed and return to
speed 2 when the probe detects that the
temperature drops below 85ºC.
DESCRIPTION OF THE DISPLAY
DESCRIPTION OF THE KEYBOARD
-Manual: In order to adjust the fan, select this
option using the MODE button
enable you to increase the speed of the fan by
pressing the
FAN button and selecting one
of the four options AUTO
MEDIUM
/ MAXIMUM
the device manually, you may increase the speed
of the fan in relation to the speed selected by the
automatic function, you will not be allowed to
reduce the speed of the fan below the speed
established by the automatic function or stop
the fan if the automatic function is connected.
If you activate the fan when there is no
temperature, the fan will stop two hours after
the last time the remote control was used
COMBUSTION AIR ADJUSTMENT.
When the compact device is plugged into a
power socket, the valve resets into the open
position. This operation takes place whenever
the device is unplugged and then plugged in
again or when the power supply is re-
established after a power cut.
- Use the valve option in the MODE selector
Once the symbol appears on
to adjust the valve.
the display, use ^ TEMP+ to open the valve and ˅
TEMP- to close the valve (press repeatedly until
the desired valve position appears on the
display)
The motorised valve has 5 defined positions.
These positions are displayed by means of a
series of horizontal bars.
VALVE CLOSED
VALVE OPEN ¼
VALVE OPEN 2/4
VALVE OPEN ¾
VALVE FULLY OPEN
This will
/MINIMUM
/
When operating
.